Tbbx/J Series Indoor 6-10kV 50HZ Centralization High-Voltage HV Shunt Capacitor Reactive Power Local Compensation Device Cabinet with Capacitor Over-Pressure Protection Installations PF Correction with Capacitor for three-phase AC motor
Tbbx/J Series Indoor 6-10kV 50HZ Centralization High-Voltage HV Shunt Capacitor Reactive Power Local Compensation Device Cabinet with Capacitor Over-Pressure Protection Installations PF Correction with Capacitor for three-phase AC motor

Tbbx/J Series Indoor 6-10kV 50HZ Centralization High-Voltage HV Shunt Capacitor Reactive Power Local Compensation Device Cabinet with Capacitor Over-Pressure Protection Installations PF Correction with Capacitor for three-phase AC motor

USD $1500 - $6000 /Set

Min.Order:1 Set

Supply Ability:
5000 Set / Sets per Month
Port:
Chongqing
Payment Terms:
T/T
Delivery Detail:
15 days

Quick Details View All >

Brand Name:
Enrich
Place of Origin:
China
Model Number:
TBBX/J10-450-(J)

Chongqing Enrich Engineering and Technology Co., Ltd

Business Type: Trading Company
Chongqing China
Main Products: hydropower plant equipments ,electric power equipments ,power distribution equipments ,hydro turbine generator ,Industrial water filter&oil purifier ,Instrument transformer ,Power quality monitoring&improvement ,Reactor/Inductor ,Busduct ,Circuit breaker&Isolating switch&Load switch ,Filter press ,Slurry Pump

Product Details

TBBX/J Series high-voltage reactive power local compensation device

 

Model description

TBBX/J10-450-(J)

TBB: Shunt capacitor device

X/J: Local compensation

10: Rated voltage (kV)

450: Rated capacity (kVar)

J: Simple type, not marked as vacuum contactor switching type

 

TBBX/J high-voltage reactive power local compensation device (hereinafter referred to compensation device) is indoor type, rated voltage 6-10kV, frequency 50Hz, for local reactive power compensation for three-phase AC motor with rated voltage 6-10KV. It reduces electrical energy consumption, improve grid voltage quality, and improve motor starting performance. The capacitor in the compensation device is turned on when the motor start, cut off when stop. It is a novel energy-saving product with a compensation effect more better than centralized compensation.

It is suitable for reactive power compensation of high-power motors in smelting, steel, mining, building materials, cement, water supply and drainage and transportation industries.

 

Features

1.The products are divided into simple type and vacuum contactor switching type. The simple product capacitor is directly connected to the motor terminals through a fuse. The compensation device current does not exceed 90% of the no-load current of the motor to avoid overvoltage damage to the motor due to self-excitation after shutdown. Power factor after compensation may not be too high, generally around 0.9. Using vacuum contactor switching, the compensation capacity can be larger, and the power factor can be more than 0.95 after compensation.

2.The vacuum contactor is switched on and off, and the motor switch is switched on and off, and the compensation device is also input, the device vacuum switch tripping, the capacitor off and the discharge coil are automatically discharged.

3.The shell of the compensating device is combination of cabinet sections or made of bending and welding steel plates. The upper part of the cabinet is the instrument door where the instrument is installed, and the lower part is the steel door with safety lock.

4.Compensation device cable/bus entry method: cable lower entry method or overhead bus upper entry method.

 

Main technical parameters

1.Rated voltage: 6kV, 10kV.

2.Rated frequency: 50Hz.

3.Rated capacity: 50-1000kvar.

4.Structure: cabinet type.

5.Capacitor connection: star connection.

6.Working mode: following the motor.

 

Normal conditions of use

1.Indoor use.

2.The altitude does not exceed 2000m.

3. The ambient air temperature is-10 ℃~+ 40℃.

4. No severe mold, no corrosive gas, no severe dust, no electric dust, and no severe vibration at the installation site.

5.Relative humidity: daily average is not more than 95%, monthly average is not more than 90%.

6. The device is only suitable for the continuous working system of the motor, and there is no large impact load. It can’t be used for reverse connection for braking. It should not be used on the motor load of adjusting control.

 

No.

Model

Rated voltage Un/kV

Capacitor bank rated current In/A

Shunt capacitor model

1

TBBX6-90

6.6

7.9

BFM6.6/3-30-1

2

TBBX6-150

6.6

13.1

BFM6.6/3-50-1

3

TBBX6-200

6.6

17.5

BFM6.6-200-3

4

TBBX6-300

6.6

26.2

BFM6.6/3-100-1

5

TBBX6-600

6.6

52.5

BFM6.6/3-200-1

6

TBBX10-90

10

4.7

BFM11/3-30-1

7

TBBX10-150

 

10

7.9

BFM11/3-50-1

8

TBBX10-200

10

10.5

BFM11-200-3

9

TBBX10-300

10

15.75

BFM11/3-100-1

10


TBBX10-450

 

10

23.6

BFM11/3-150-1

11

TBBX10-600

10

31.5

BFM11/3-200-1

12

TBBX10-900

 

10

47.2

BFM11/3-300-1

13

TBBX10-1000

10

52.6

BFM11/3-334-1

 


Contact Supplier

Mr. Guangjian Duan Sales director Chat Now
Telephone
86-23-62540401
Mobile
86-13647680724
Fax
86-23-62540401
Skype
Guangjian Duan
Address
No. 6 building, No. 1 Minyue Road,Jiangbei District Chongqing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Power Distribution Equipment
Categories
Hi~