Product Description
1 Introduction
The medical IT system is mainly used in important Class 2 medical locations such as operating room, ICU/CCU intensive care unit, providing safe, reliable and continuous power distribution for the important equipment at these locations. Medical insulation monitoring and fault locating device is developed by the many years’ design experience of the Acrel Electric in electric power meter industry, according to the special requirements of the insulation monitoring and fault locating of the power distribution system in Class 2 medical locations. The products can realize the real-time monitoring of insulation, load and temperature of isolation transformer in IT system, and have the functions of system insulation fault loop positioning and centralized monitoring by multiple pieces of systems. Products conform to the provisions of enterprise standard Q31/0114000129C013-2016 IT System Insulation Monitoring Instrument.Medical IT system insulation monitoring and fault locating products (seven-piece set) include AITR series
medical isolation transformer, AIM-M200 medical intelligent insulation monitoring instrument, AKH-0.66P26 current transformer, AIL100-4/AIL100-8 insulation fault locator, ASG100 test signal generator, DR-60-24 power module and AID200 centralized alarm and display instrument, which are shown in Table 1.
2 Function features
Function features of AITR series medical isolation transformer
The transformation ratio between the primary and secondary windings is 1:1;
Double insulation treatment is adopted between the windings, and the electrostatic shielding layer is designed.
The PT100 temperature sensor is installed in each wire packet to monitor the temperature of the isolation
transformer;
Used for the transformation of TN system into IT system (ungrounded system) after isolation transformer.
4 Technical parameters
Technical parameters of AITR series medical isolation transformer
Table 2 Technical Parameters of AITR Series of Medical Isolation Transformer
5 Installation and wiring
5.1 Shape and mounting hole size
5.1.1 External dimensions of AITR series medical isolation transformer (unit: mm)
Shape structure and size of AITR series medical isolation transformer are shown as below and in Table 9 (unit: mm)
Table 9 External Dimensions of AITR Series Medical Isolation Transformer
Company Information
Technical Consult
You May Like
- Acrel AITR-3150 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-8000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-5000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-5000 insulation system hospital isolated 5kva medical isolation transformer
- Acrel 300286 AKH-0.66P26 Medical isolation grade current transformer for Hospital Isolated Power System
- Acrel 300286 AID150 Medical isolation Nurse Station Alarm device for Hospital Isolated Power System
- Acrel AITR-8000 hospital isolated 230V isolation transformer for insulation system
- Acrel AITR-10000 insulation system hospital isolated 230V transformer for medical isolation
- Acrel AITR-10000 hospital isolated 230V isolation transformer for insulation system
- Acrel AITR-6300 hospital isolated 230V isolation transformer for insulation system
Popular Searches
power transformer
Distribution Service
current transformer
power transformers
High Frequency Transformer
Electrical Transformer
energy saver device
led transformers
step up converter
Ac Drive Converter
Frequency Drive Converter
electronic transformer
Lighting Transformers
toroidal transformer
auto transformer
current transformer inductor
Find Similar Products By Category
You May Like
- Acrel 300286 AClP10-24 Medical isolation power supply for Hospital Isolated Power System
- Acrel AITR-3150 hospital isolated 230V isolation transformer for insulation system
- Acrel ACLP10-24 Isolated Power Monitor System for Hospital power supply
- Acrel professional DC voltage stabilizer ACLP10-24 ACREL factory direct.SZ
- Acrel DC regulated power supply for hospital IT insulation system ACLP10-24
- Acrel ACLP10-24 DC24V automatic voltage stabilizer
- Acrel DC voltage stabilizer for insulation monitoring device ACLP10-24
- DC voltage stabilizer for isolated power supply cabinet from Acral ACLP10-24
- hot selling DC voltage stabilizer for IT insulation system Acrel ACLP10-24
- High Quality single phase DC24V voltage stabilizer ACLP10-24 ACREL factory direct.SZ
- Acrel 300286 AIM-M100 Medical isolation monitoring device for Hospital Isolated Power System
- Acrel ACLP10-24 DC regulated power supply din rail installation
- Acrel universal type DC voltage stabilizer with low price ACLP10-24
- Acrel AIM-M10 medical intelligent insulation monitoring instrument with LED alarm indication
- Acrel AIM-M10 medical intelligent insulation monitoring instrument with faults indication functions