Product Description
ARD2F Smart Motor Protector
ARD2F Smart Motor Protector
General
ARD series intelligent motor protector (hereinafter referred to as protector) can perform various conditions such as start
timeout, overload, phase failure, unbalance, underload, ground/leakage, blockage, short circuit and external fault during motor operation. Protection, and SOE fault event recording function, convenient for on-site maintenance personnel to find the cause of the fault. Suitable for coal, petrochemical, smelting, electric power, ships, and civil construction. The protector has RS485 remote communication interface, DC 4 ~ 20mA analog output, and PLC, PC and other control machines form a network system. Remote monitoring of motor operation.
Features
● Measurement functions are divided into basic measurement (current parameter) and co-selection measurement (voltage, power, phase sequence, residual current (leakage current);
● Start timeout, overload, stall, block, underload, phase failure, unbalance, residual current (ground/leakage), temperature,
external fault, phase sequence, overvoltage, undervoltage, underpower, overpower, tE time Motor comprehensive protection function;
● 9-channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 5-channels DO output, which can meet the direct start, star-delta start, autotransformer start, soft start and other starting modes. Real-time remote control "start/stop" operation of the remote master station can be realized through the communication bus;
● It has standard RS485 communication interface and adopts Modbus-RTU and Profibus-DP communication protocol to ensure fast and reliable communication of the host computer;
● It has a DC4-20mA analog output interface and is directly connected to the DCS system to monitor the field devices.
● Start timeout, overload, stall, block, underload, phase failure, unbalance, residual current (ground/leakage), temperature,
external fault, phase sequence, overvoltage, undervoltage, underpower, overpower, tE time Motor comprehensive protection function;
● 9-channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 5-channels DO output, which can meet the direct start, star-delta start, autotransformer start, soft start and other starting modes. Real-time remote control "start/stop" operation of the remote master station can be realized through the communication bus;
● It has standard RS485 communication interface and adopts Modbus-RTU and Profibus-DP communication protocol to ensure fast and reliable communication of the host computer;
● It has a DC4-20mA analog output interface and is directly connected to the DCS system to monitor the field devices.
Technical Parameters
Technical data of motor protector ARD2F-25 | ||||
Auxiliary power supply of protector | AC85V~265V/DC100V~350V, power consumption ≤7VA | |||
Rated working voltage of motor | AC380V/AC660V, 50H/60Hz | |||
Rated working current of motor | 1A(0.1 ~9999) | Small specific current transformer | ||
5A(0.1 ~9999) | ||||
1.6A(0.4A—1.6A) | ||||
6.3A(1.6A~6.3A) | ||||
25A(6.3A~25A) | ||||
100A(25A~100A) | ||||
250A(63A-250A) | Specific current transformer | |||
800A(250A~800A) | ||||
Relay output contactor, rated load capacity | 4-way,AC250V, 3A, DC30V, 3A | |||
Switching input | 2-way, optical isolation | |||
Communication | RS485 Modbus | |||
Volume of SOE event recorder | 8 events | |||
Environment | Working temperature | -10℃-55℃ | ||
Storage temperature | -20℃-65℃ | |||
Relative humidity | 5%-95%, no dew | |||
Altitude | ≤2000m | |||
Class of pollution | 2 | |||
Protection level | IP20 |
Rated current of motor protector(A) | current ratio setting | Transformer primary side turns | Setting current Is range(A) | Motor Power(kW) |
1 | able to set | 5 | 0.1~9999 | 0.12~440 |
5 | 1 | 0.1~9999 | 0.12~440 | |
1.6 | unable to set | 1 | 0.4~1.6 | 0.12~0.55 |
6.3 | 1 | 1.6~6.3 | 0.75~2.2 | |
25 | 1 | 6.3~25 | 3~11 | |
100 | 1 | 25~100 | 15~45 | |
250 | 1 | 63~250 | 55~132 | |
800 | 1 | 250~800 | 160~440 |
Function
LCD Display
Typical connection
Quotation
You May Like
- Acrel 300286.SZ ARD2F-25+90L lcd display motor unbalance protector used in smelting plant
- Acrel 300286.SZ ARD2F-25+90L lcd display smart motor protector used in coal mine industry
- Acrel AGF-M4T meter for solar pv
- Acrel AGF-M4T day meter for combiner box in solar energy system
- Acrel AGF-M4T 1hp water pump 60 meters borehole for strings solar combiner box
- Acrel AGF-M4T tester meters for solar pv array combiner box
- Acrel AGF-M4T 10kw inverter with smart meter for combined box PV solar
- Acrel AGF-M4T smart energy meter 8 string combiner box for solar panels
- Acrel AGF-M4T 500 meter long range 10 multi channel transmitter and for solar panel set 3kva vp array combiner box
- Acrel AGF-M4T deep well 400 meter head pump for solar panel set 3kva vp array combiner box
Popular Searches
Find Similar Products By Category
You May Like
- Acrel AGF-M4T smart meter solar combiner box for 5kw
- Acrel AGF-M4T current flow meter for solar pv smart combiner box
- Acrel AGF-M4T solar-meter - d) ref combiner box for solarar panel PV
- Acrel AGF-M4T current charger meter for solar combiner box with disconnect
- Acrel AGF-M4T solar meter 9.6 for combination ev/solar chargers
- Acrel AGF-M4T pump 130 meters head for pv solar combiner box
- Acrel AGF-M4T watt meter controller for special combination inverters solar
- Acrel AGF-M4T digital meter sunnof for solar combiner box
- Acrel AGF-M4T power meter PV for PV solar pv combiner box 5input and 5output
- Acrel AGF-M4T grid tied meter residential for strings solar combiner box
- Acrel AGF-M4T two way meter panals for 6 in 2 out solar pv combiner box
- Acrel AGF-M4T film transmission meter for solar panel combiner box
- Acrel AGF-M4T panel square meter for 6 in 2 out solar pv combiner box
- Acrel AGF-M4T power meter connect to grids combiner box for solar panel PV
- Acrel AGF-M4T pv clamp meter for inverter solar combine with wind