PZ72L-DE Smart Panel mounted DC Energy Meter
PZ72L-DE Smart Panel mounted DC Energy Meter
General
PZ series intelligent DC energy meter is designed for applications such as DC panels, solar power, telecommunications base stations,and charging posts. This series of instruments can measure voltage, current, power, forward and reverse power in DC system. It can be used for local display, and connected with industrial control equipment, computers, form a measurement and control system. And it has a variety of external excuse functions for the user to choose: RS485 communication interface, Modbus-RTU protocol, relay alarm output, digital input/output. According to different requirements, through the instrument panel keys, you can set the ratio, communication parameters.
Types and Functions
Type | Basic Function | Exterior | Optional Function | |||
PZ72L-DE | voltage、current、power、energy、LCD desplay | 72 square | 1.--RS485 (/C) 2.--12V power output① (/V) 3.--RS485 + 2DO (/KC) 4.--RS485 + 2DI2DO (/KC) 5.--RS485 + 2DO + 12V power output (/KVC) 6.--RS485 + 12V power output (VC) The above functions can have the following two optional functions at the same time: 7.--Auxiliary power 20-60V (/ZD) 8.--Multiple rate (F) | |||
PZ72-DE | voltage、current、power、energy、LCD desplay | |||||
Annotation: ①The functon of 12V power output and DI can not be selected at the same time. |
Technical Parameters
Technical Parameters | Indicators | ||||||
Input | DC voltage | Input range | 0~100V,0~500V,0~1000V | ||||
Input resistance | ≥6kΩ/V | ||||||
DC current | Input range | (External Shunt or Hall Current Sensor, the range can be set) | |||||
Shunt | 75mV | ||||||
Hall Current Sensor | 0~20mA、0~5V | ||||||
Power consumption | ≤1mW | ||||||
Overload | It can work at normal status at 1.2 times of full load, and can contined work 1 second at 2 times of full load. | ||||||
Accuracy class | 0.5class | ||||||
Function | Measuring | Voltage、Current、Power | |||||
Calculate | Current total electricity、Current positive energy、Current reverse power | ||||||
Multiple rate | Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only) | ||||||
Historical data statistics | Last 12 months of historical electricity(multiple rate electricity).(PZ72L-DE support only) | ||||||
DI、DO | 2DI(Collect and display local switch status information、Realize remote transmission by RS485)、2DO(Relay output, can achieve "remote control" and alarm output) | ||||||
Display | LCD(the backlight delay time can be adjusted) or LED | ||||||
Communication | RS485、Half duplex、Photoelectric isolation、Modbud-RTU / DL/T645-07、Band:1200/2400/4800/9600、Infrared:1200 | ||||||
DI、DO | DI | Dry contact input, Meter built-in power supply, photoelectric isolation | |||||
DO | Two relay outputs, Normally open contact, capacity:2A/30VDC or 2A/250VAC | ||||||
Working power | Voltage range | 85~265VAC/DC、50/60Hz;20~60VDC | |||||
Power consumption | ≤2W | ||||||
Insulation resistance | ≥100MΩ | ||||||
Power frequency withstand voltage | 3kV/1min(RMS)(between the power supply binding post and the signal binding post) | ||||||
Environment | Temperature | Working Temp:-20℃~+60℃;Storage Temp:-20℃~+70℃ | |||||
Humidity | ≤ 93%RH No condensation, no corrosive gases | ||||||
Altitude | ≤ 2500m |
You May Like
- Acrel 300286.SZ panel mounted DC system 0-1000V input power meter PZ72L-DE
- Acrel 300286.SZ Telecommunications base stations used DC digital power meter PZ72L-DE
- Acrel 300286.SZ panel mounted solar power DC energy meter PZ72L-DE
- Acrel AMC16MA Data Center Monitoring 3P4 Wmulti-channel energy meter/multi-circuit power meter/RS485 multi-loop power meter
- Acrel AMC16MA Data Center Monitoring multi-circuit energy meter/multi-channel power meter/RS485 multi-loop energy meter
- Acrel 300286.SZ panel mounted smart power meter PZ72L-DE for DC panels
- Acrel WHD20R-22 Digital Temperature and Humidity Controller used for terminal box CE
- Acrel AM4-I self-produced over zero-current alarm medium voltage application protection relay
- Acrel AMC72L-AV/C Programmable voltmeter 67*67mm,LCD display with RS485(MODBUS RTU)
- Acrel AMC72L-AV3/CJM three phase Programmable voltmeter Input:AC100v,220v,380v with RS485,analog output, alarm
Popular Searches
Find Similar Products By Category
You May Like
- Acrel AMC72L-AV3/KC LCD display three phase voltmeter with RS485 and 2DI/2DO
- Acrel AMC72L-AV3/J three phase Programmable voltmeter with alarm function
- Acrel AMC72L-AV3/K 3P4W LCD display voltmeter with 2DI2DO 67*67mm
- Acrel AMC72L-AV3/C three phase Programmable voltmeter Input:AC100v,220v,380v with RS485(MODBUS-RTU)
- Acrel AMC72L-AV3 3P4W Programmable voltmeter 67*67mm,LCD display
- Acrel 300286.SZ AMC96-E4/KC 3P4W rs485 power collection and monitoring electrical digital energy meter with CE approval
- Acrel 300286.SZ AMC96-E4/KC LCD display rs485 modbus 3 phase digital kwh energy meter with 4DI/2DO
- Acrel 300286.SZ AMC96-E4/KC 96*96mm CE 3P4W multifunction harmonic electrical digital energy meter with lcd display
- Acrel 300286.SZ AMC96-E4/KC 96*96mm harmonic watt-hour meter with rs485 communication
- Acrel 300286.SZ AMC96-E4/KC LCD display three phase smart energy meter with rs485 4DI/2DO
- Acrel AM4-I overvoltage protection medium voltage application protection relay
- Acrel 300286.SZ AMC96-E4/KC 3P3W 3P4W multifunction harmonic energy meter with CE approval
- Acrel 300286.SZ ARTU-K32 smart power distribution used remote terminal unit/RTU rs485 Modbus-rtu
- Acrel 300286.SZ din rail mounting remote terminal unit with rs485 modbus rtu recording function ARTU-K32
- Acrel 300286.SZ ARTU-K32 din rail data exchange remote terminal unit with recording function