Acrel 300286.SZ DC panel KWH power analyzer PZ72L-DE/K with abnormal alarm for solar power
USD $95.2 - $95.2 /Piece
Min.Order:1 Piece
Jiangsu Acrel Electrical Manufacturing CO.,LTD
Acrel 300286.SZ panel multifunctional power meter 2DI/2DO PZ72L-DE/K for solar power
Acrel 300286.SZ DCdigital panel rs485 energy meter PZ72L-DE/C for charging pile with CE certificate
Acrel 300286.SZ panel mounted DC system 0-1000V input power meter PZ72L-DE
Acrel 300286.SZ Telecommunications base stations used DC digital power meter PZ72L-DE
Type | Basic Function | Exterior | Optional Function | |||
PZ72L-DE | voltage、current、power、energy、LCD desplay | 72 square | 1.--RS485 (/C) 2.--12V power output① (/V) 3.--RS485 + 2DO (/KC) 4.--RS485 + 2DI2DO (/KC) 5.--RS485 + 2DO + 12V power output (/KVC) 6.--RS485 + 12V power output (VC) The above functions can have the following two optional functions at the same time: 7.--Auxiliary power 20-60V (/ZD) 8.--Multiple rate (F) | |||
PZ72-DE | voltage、current、power、energy、LCD desplay | |||||
Annotation: ①The functon of 12V power output and DI can not be selected at the same time. |
Technical Parameters | Indicators | ||||||
Input | DC voltage | Input range | 0~100V,0~500V,0~1000V | ||||
Input resistance | ≥6kΩ/V | ||||||
DC current | Input range | (External Shunt or Hall Current Sensor, the range can be set) | |||||
Shunt | 75mV | ||||||
Hall Current Sensor | 0~20mA、0~5V | ||||||
Power consumption | ≤1mW | ||||||
Overload | It can work at normal status at 1.2 times of full load, and can contined work 1 second at 2 times of full load. | ||||||
Accuracy class | 0.5class | ||||||
Function | Measuring | Voltage、Current、Power | |||||
Calculate | Current total electricity、Current positive energy、Current reverse power | ||||||
Multiple rate | Four time zones、two time table、fourteen time points、four multiple rates. (PZ72L-DE support only) | ||||||
Historical data statistics | Last 12 months of historical electricity(multiple rate electricity).(PZ72L-DE support only) | ||||||
DI、DO | 2DI(Collect and display local switch status information、Realize remote transmission by RS485)、2DO(Relay output, can achieve "remote control" and alarm output) | ||||||
Display | LCD(the backlight delay time can be adjusted) or LED | ||||||
Communication | RS485、Half duplex、Photoelectric isolation、Modbud-RTU / DL/T645-07、Band:1200/2400/4800/9600、Infrared:1200 | ||||||
DI、DO | DI | Dry contact input, Meter built-in power supply, photoelectric isolation | |||||
DO | Two relay outputs, Normally open contact, capacity:2A/30VDC or 2A/250VAC | ||||||
Working power | Voltage range | 85~265VAC/DC、50/60Hz;20~60VDC | |||||
Power consumption | ≤2W | ||||||
Insulation resistance | ≥100MΩ | ||||||
Power frequency withstand voltage | 3kV/1min(RMS)(between the power supply binding post and the signal binding post) | ||||||
Environment | Temperature | Working Temp:-20℃~+60℃;Storage Temp:-20℃~+70℃ | |||||
Humidity | ≤ 93%RH No condensation, no corrosive gases | ||||||
Altitude | ≤ 2500m |