Product Description
BA10-AI/I Current Transducer
BA10-AI/I Current Transducer
General
BA series conduct the real-time measurement on the alternating current in the power grid according to the electromagnetic induction theory. They utilize the precise constant current technology and the linear temperature
compensation technology to isolate and convert the measured current into the DC signal. They adopt the 24V or 12V power supply.They feature the large overload capacity,high accuracy,isolation and safety and low power consumption.Application cover the industrial automation sector.
BA series residual current sensors are designed to monitor the electric leakage and detect the insulation of electrical circuit or electrical equipment in order to avoid accidents arising from reduction of insulation performance of electrical circuit orelectrical equipment.The product complies with GB/T13850-1998 and GB1208-2006..
Features
- Direct AC current measurement up to 600A
- Overload: 1.2 times of rated value
- Overload: 1.2 times of rated value
- Applied in Industrial automation
Technical Parameter
Model Technical parameters | BA05 | BA10 | BA20 | BA50 | ||||||||||||
Accuracy | 0.5class、0.2class | |||||||||||||||
Input | Nominal value | AC0~(0.5~10)A | AC 0~( 8~50)A | AC 0~(40~200)A | AC 0~(60~600)A | |||||||||||
Overload | Continual1.2 times, Instantaneous current 10 times/1s: | |||||||||||||||
Absorbed power | ≤1VA | |||||||||||||||
Frequency response | 25Hz~800Hz(average), 25~5kHz(true RMS),specially suitable for power frequency application | |||||||||||||||
Output | Nominal value | DC4~20mA,or 0~20mA,0~5V,0~10V(And so on) | ||||||||||||||
Load resistance | Current output ≤500Ω , Voltage output≥1KΩ | |||||||||||||||
Response time | Average≤350ms, true RMS≤100ms | |||||||||||||||
Power supply | Voltage | DC12V or 24V | ||||||||||||||
Consumption | ≤1W | |||||||||||||||
Insulation resistance | >100MΩ | |||||||||||||||
Isolation voltage | (Among input//output//power supply)2.0kV/1min,50Hz | |||||||||||||||
Temperature modulus | -10℃~+55℃,≤100ppm/℃ | |||||||||||||||
Environment | Temperature | Work:-10℃~+55℃ Storage:-25℃~+70℃ | ||||||||||||||
Humidity | ≤93%RH,(In the place without dew and corrosive gas) | |||||||||||||||
Altitude | ≤2000m | |||||||||||||||
Installation | (TS35 rail mounting, or attached with screws in of the cabinet) |
Product Specification
Model | Product function | Perforation(mm) | Enter the nominal value range |
BA05-AI/I(V) | 0-10A AC current signal acquisition, output 4-20mA or 0-5V DC signal | Φ5 | AC0~(0.5~10)A |
BA05-AI/I(V)-T | |||
BA10-AI/I(V) | 0-50A AC current signal acquisition, output 4-20mA or 0-5V DC signal | Φ10 | AC0~(8~50)A |
BA10-AI/I(V)-T | |||
BA20-AI/I(V) | AC 0-200A current signal acquisition, output 4-20mA or 0-5V DC signal | Φ20 | AC0~(40~200)A |
BA20-AI/I(V)-T | |||
BA50-AI/I(V) | AC 0-600A current signal acquisition, output 4-20mA or 0-5V DC signal | Φ50 | AC0~(60~600)A |
BA50-AI/I(V)-T |
Quatation sheet
You May Like
- Acrel 300286.SZ AC current sensor BA10- AI/I aperture 10mm with 0-50A in 4-20mA analog output
- Acrel 300286.SZ BA10- AI/V AC current transmitter with 0-50A input 0-5V Analog output
- Acrel 300286.SZ AC current transmitter BA10- AI/I with 0-50A in 4-20mA analog output
- Acrel 300286.SZ analog output 3 phase electricity transducer BD-3I3
- Acrel 300286.SZ single phase electricity transducer BD-AI with analog output
- Acrel 300286.SZ 3P3W input 0-5A/450V active power electricity transducer BD-3P with analog output
- Acrel AKH-0.66/L-45 clamp leakage for network monitoring weak current equipment
- Acrel AKH-0.66/L-45 residual release for monitor the voltage and current of 108 batteries sensor
- Acrel AKH-0.66/L-45 auto reclosing residual sensor for voltage current meter power monitor
- Acrel AKH-0.66/L-45 ac leakage for online monitoring current clamp sensor
Popular Searches
lightning conductor
Copper Lightning Rod
Lightning Rod Clamp Earth Rod
earthing system
transmission rod
11 kv lightning arrester
Copper Clad Steel Ground Rod
static eliminator
anti static device
Air Blower Electrostatic Eliminator
lightning connector
plasma tv lift
mtl safety barrier
copper earthing bar
copper earthing rods
electrical earth rod
Find Similar Products By Category
You May Like
- Acrel AKH-0.66/L-45 wet leakage tester for measure current monitor
- Acrel AKH-0.66/L-45 residual sensor for current monitoring sensor
- Acrel AKH-0.66/L-45 residual circuit break for monitor the voltage and current of 108 batteries sensor
- Acrel AKH-0.66/L-45 rcbo circuit breaker residual for real-time current monitor
- Acrel AKH-0.66/L-45 clamp leakage for voltage current meter power monitor
- Acrel AKH-0.66/L-45 sensor measure 20 amp residual device for current monitoring sensor
- Acrel AKH-0.66/L-45 current-operated earth-leakage circuit-breaker for real-time current monitor
- Acrel AKH-0.66/L-45 leakage clamp for residual monitor current
- Acrel AKH-0.66/L-45 residual circuit breaker 315a for 30a current monitoring board
- Acrel AKH-0.66/L-45 current-operated earth-leakage circuit-breaker for 30a current monitoring board
- Acrel AKH-0.66/L-45 residual type a for sensor current monitor 4418
- Acrel AKH-0.66/L-45 leakage transformer for 30a current monitoring board
- Acrel AKH-0.66/L-45 residual-current device for voltage current meter power monitor
- Acrel AKH-0.66/L-45 voltage and leakage tester for current monitor microamp
- Acrel AKH-0.66/L-45 rated residual circuit breaker for current monitor pcb