Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter
Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter
Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter
Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter
Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter
Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter
Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter

Acrel AHKC-BS uninterruptible power supplies extended measuring range hall sensor split core current transmitter

USD $7 - $7 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Acrel
Place of Origin:
Jiangsu, China
Model Number:
AHKC-BS

Jiangsu Acrel Electrical Manufacturing CO.,LTD

Business license
Business Type: Manufacturer
Wuxi Jiangsu China
Main Products: power sensor ,programmable power meter ,DC power analyzer ,Data center monitor device ,Din rail energy meter ,Isolated power supply ,wireless temperature sensor ,IOT energy meter ,split core current transformer

Product Details

AHKC-BS Hall Sensor
Measurement
- AC, DC, pulse and other complex current

Appearance
- Small package size
- Low power consumption
- Extended measuring range
Input
0-50-500A
Output
5V/4V


Power supply

±15V


Accuracy

1 class


Attention: 1. When the hall sensor is used, in order to obtain better dynamic characteristics and sensitivity, attention must be paid to the coupling between the primary side coil and the secondary side coil. It is recommended to use a single wire and the wire completely fills the hall sensor module wire hole;
2. When the hall sensor is used, the best measurement accuracy can be obtained under the rated input current value. When the measured current is far lower than the rated current To obtain the best accuracy, multiple turns can be used for the primary side, i.e. IPNP = rated ampere turns. In addition, the temperature of the primary side feeder shall not exceed 80 ℃;
3. The auxiliary power supply of Hall current sensor shall not exceed ± 20% of the calibrated value when it works normally; 4. Hall current sensor shall not fall from a high place (≥ 1m) during installation and use; 5. It is unable to adjust the zero point and full degree adjustment potentiometer; 6. Auxiliary power supply needs to be configured by itself; 7. The positive and negative poles of the power supply cannot be reversed.

Contact Supplier

Mr. Tim Overseas sales engin Chat Now
Telephone
86-1870-6168051
Mobile
86-18761599716
Fax
86-1870-86179975
Skype
86 18761599716
Address
Jiangyin Wuxi,Jiangsu
Whatsapp
86 18761599716

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Hi~