Boil Testing Device for Laminated and Organic Coated Glazing
USD $300 - $650 /Set
Min.Order:1 Set
Qinhuangdao Yuanchen Hardware Co.,Ltd
1) EN ISO 12543 - 4 Glass in building -Laminated glass and laminated safety glass - Part 4: Test methods for durability – Clause 5 High-temperature test
2) AS/NZS 2208 Safety glazing materials in buildings – Appendix F Boil Test
3) GB 15763.3 Safety glazing materials in building Part 3:Laminated glass – Clause 7.8 Heat resistance test
4) ANSI Z97.1 Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test - Clause 5.3.2 – ( 1 ) Boil Test
Data:
5) Power: 220V 50Hz 3Kw (Customized)
6) Outside Size: 430mm*290mm*575 mm
7) Inner Size: 400mm*255mm*480mm
8) Rack:340mm*235mm*350mm
9) At most 6 samples with 300mm*300mm
Scope:
10) Determining the effect of exposure of safety glazing materials to temperature and humidity condition by boiling
Principle:
11) Specimens are immerse in hot water and boiling water for specified period of time and inspect bubbles and others defects
Apparatus:
12) The apparatus include two water baths, each of sufficient size to hold the test specimen fully immersed vertically on edge for the duration test.
Samples:
13) Three specimen of size 300mm*300mm manufacture in a manner identical with impact test specimens and of like thickness shall be tested.
14) These specimens may be cut from production samples of the size and thickness submitted for impact testing.
15) For heat strengthened or toughened laminated glass, test specimen may be cut from a similar original sheet of annealed laminated glass
Procedure:
16) Immerse the specimens vertically on edge in a bath of water maintained at a temperature of 66°C±3°C for 3 min
17) Quickly transfer the specimens to a bath of water maintain at boiling point. Immerse the specimens vertically on edge for 2 h
18) Remove the specimens and examine for the bubbles and others defects