Acrel solar power charger energy meter ACR10-D24TE4
Acrel solar power charger energy meter ACR10-D24TE4
Acrel solar power charger energy meter ACR10-D24TE4
Acrel solar power charger energy meter ACR10-D24TE4

Acrel solar power charger energy meter ACR10-D24TE4

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
99999 Piece / Pieces per Month

Jiangsu Acrel Electrical Manufacturing Co.,LTD.

Business license
Main Products: energy meter

Product Details

 The rail-type multifunction electrical instrument with external Rogowski coil and split-core current transformer is applicable for the energy-saving reconstruction project in high energy consumption industries including the smelting, iron and steel, welding and semi-conductor industry. It is also suitable for applications such as the power monitoring of grid-connected cabinet for distributed photovoltaic power cabinet and energy demand management. It boasts of no need of bus removal, easy connection and safe construction, saving reconstruction cost and raising efficiency for the user.

 

Product Function

 Model Function

ACR10R-DxxTE

Measurement

Parameters

Single-phase current

 

YES

Single-phase voltage

YES

Single-phase (active power, reactive power, power factor)

YES

Three-phase (active energy, reactive energy)

YES

 

Note:1.“YES”refers to standard function, the standard configuration for above instruments is 1 channel RS485 communication.

 

Technical Parameters

Technical parameters

Indicators

Input

Grid

Single-phase,

Frequency

45~65Hz

Voltage

Rated voltage: AC 100V, 400V

Overload: 1.2 times the rated voltage(continuous); 2 times the rated voltage lasting for 1 second

Power consumption: less then 0.2VA

Current

Rated current:  10A,20A,40A,80A,120A,200A etc. (for details see product specifications)

Overload: 1.2 times the rated current(continuous);10 times the rated current lasting for 1 second

Power consumption: less then 0.2VA

Output

Communication

RS485 interface, Modbus-RTU

Display

LCD

Measurement precision

Voltage: 0.2 level, current, power Active energy: 0.5 level,0.01Hz frequency, Reactive energy: 1 level

Power supply

AC85~265V or DC100~350V; power consumption ≤10VA

Safety

Power frequency withstand voltage

AC2kV 1 min between power supply // current input//voltage input and communication

AC2kV 1 min between each pair of combinations among power supply, urrent input and voltage input.

Insulating resistor

Input,output terminal to housing >100MΩ

Environment

Working temperature: -10℃~+55℃;storage temperature: -20℃~+70℃ 

Relative humidity:5%~95%,non-condensing; altitude:≤2500m

  


Dimensions (Unit: mm)
 

 

 


Contact Supplier

Mr. Robin Wong Chat Now
Telephone
86-188-60990280
Mobile
86-18860990280

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Power Meters
Categories
Hi~