Thermocouple wires bare wire for cables and temperature measurement Type K
Negotiable /Kilogram
Min.Order:20 Kilograms
Shandong Liqun Alloy Material Co.,LTD.
Thermocouple wires bare wire for cables and temperature measurement Type K
1.Product classification and chemical composition
Product name | Polarity | Code | Nominal chemical composition(mass fraction)/% | |||
Ni | Cr | Si | Al | |||
Nickel chrome alloy wire | Positive | KP | 90 | 10 | - | - |
Nickel sillicon alloy wire | Negative | KN | 97 | - | 3 | - |
Nickel aluminum ally wire | Negative | KN | 96 | - | 1 | 3 |
2.Thermocouple allow temperature range
Alloy wire diameter/mm | The long-term use of temperature cap/ºC | The long-term use of temperature cap/ºC |
0.3 | 700 | 800 |
0.5 | 800 | 900 |
0.8,1.0 | 900 | 1000 |
1.2,1.6 | 1000 | 1100 |
2.0,2.5 | 1100 | 1200 |
3.2 | 1200 | 1300 |
3.Nickel chrome-nickel silicon ( nickel aluminum) thermocouple thermoelectric emfs and allowance
The measurement temperature/ºC | Thermoelectric emfs nominal value | I Level | II Level | ||
allowance | Thermoelectric emfs range | allowance | Thermoelectric emfs range | ||
100 | 100 | ±46 | 4 050~4 142 | ±91 | 4 005~4 187 |
200 | 200 | ±44 | 8 094~8 182 | ±88 | 8 050~8 226 |
300 | 300 | ±50 | 12 159~12 259 | ±93 | 12 116~12 302 |
400 | 16 397 | ±68 | 16 329~16 465 | ±127 | 16 270~16 524 |
500 | 20 644 | ±85 | 20 559~20 729 | ±160 | 20 484~20 804 |
600 | 24 905 | ±102 | 24 803~25 007 | ±191 | 24 714~25 096 |
700 | 29 129 | ±117 | 29 012~29 246 | ±220 | 28 909~29 349 |
800 | 33 275 | ±131 | 33 144~33 406 | ±246 | 33 029~33 521 |
900 | 37 326 | ±144 | 37 182~37 470 | ±270 | 37 056~37 596 |
1000 | 41 276 | ±156 | 41 120~41 432 | ±292 | 40 984~41 568 |
1100 | 45 119 | ±167 | 44 952~45 286 | ±312 | 44 807~45 431 |
1200 | 48 838 | - | - | ±328 | 48 510~49 166 |
1300 | 52 410 | - | - | ±340 | 52 070~52 750 |