ICU ventilator/Medical ventilator
USD $6400 - $6400 /Piece
Min.Order:1 Piece
Daoran Trade (Jilin) Co., Ltd.,
1、 Intended use
S1100 ventilator is suitable for all kinds of medical institutions; it is used for respiratory support of cardiopulmonary cerebral resuscitation; acute respiratory insufficiency or oxygenation dysfunction caused by various reasons; respiratory support during and after operation; and other patients who need ventilator treatment.
2、 Performance characteristics
1. Pneumatic and electric control mode
2. 15 inch color touch LCD
3. With capacity control, pressure limit and other working modes
4. Noninvasive and invasive ventilation mode
5. It has multiple alarm functions
6. It has the function of compliance compensation
7. High precision air oxygen mixer, stable and reliable
8. It has multi parameter display function
9. It is equipped with internal standby power supply. The utility power is cut off during operation, and it is automatically converted to standby power supply
10. Equipped with medical air compressor and ventilator of the same brand
11. Monitoring of end tidal carbon dioxide
12. It has screen operation button freezing function and breathing ring freezing function
3、 Working conditions
1. Supply voltage 220 V ± 22 V ~
2. Power frequency 50 Hz ± 1 Hz
3. Input power 1030va (equipped with medical air compressor)
80va (without medical air compressor)
4. Air source O2, air (medical grade)
5. Air source pressure 280 kPa ~ 600 kPa
6. Ambient temperature range + 5 ℃~ + 40 ℃
7. Relative humidity range ≤ 80%
8. Atmospheric pressure range: 700 hpa-1060 HPA
4、 Ventilation mode
1. Intermittent positive pressure ventilation (IPPV)
2. Volume control assisted / controlled ventilation mode (V-A / C)
3. Pressure control assisted / controlled ventilation mode (P-A / C)
4. Volume control synchronous intermittent mandatory ventilation mode (v-simv)
5. Pressure controlled synchronous intermittent mandatory ventilation (P-SIMV)
6. Pressure controlled ventilation mode (PCV)
7. Pressure support ventilation mode (PSV)
8. Spontaneous breathing / continuous positive airway pressure (spont / CPAP)
9. PRVC mode [optional]
10. Airway pressure relief ventilation mode (APRV) [optional]
11. Dual phase positive airway pressure (duolevel) [optional]
12. Sighing ventilation mode (sight)
13. Manual ventilation mode (Maun)
5、 Main technical indicators
tune parameter
1. Frequency (freq) 1 / min ~ 100 / min
SIMV mode: 1 / min ~ 40 / min,
Except SIMV mode: Vth 4 / min ~ 40 / min,
VTL 20 /min~ 100 /min
2. Inspiratory time (inspiratory to expiratory ratio) (tinsp) 0, 0.2 s-12.0 s (except SIMV mode, inspiratory / expiratory ratio: 4:1-1:8)
3. Tidal volume (VT) 0, 20 ml-2000 ml
(VTH:250 mL ~ 2000 mL VTL:0,20 mL~ 300 mL)
4. Minute maximum ventilation volume (MV) Vth: ≥ 18 L / min
VTL:≥10 L/min
5. Positive end expiratory pressure (PEEP) 0 cmH2O ~ 40 cmH2O
6. Continuous pressure (CPAP) 0 cmH2O ~ 20 cmH2O
7. Continuous airflow Vth: 7 L / min ~ 60 L / min
VTL:2 L/min ~ 30 L/min
8. Pressure triggered sensitivity (PTR) - 20 cmH2O ~ 0 cmH2O (based on PEEP)
9. Pressure control (PC) 5 cmH2O ~ 60 cmH2O
10. Pressure support (PS) 0 cmH2O ~ 60 cmH2O
11. The flow triggering sensitivity (FTR) was closed, 0.5 L / min ~ 30 L / min
12. Adjust the concentration of inhaled oxygen by 21% ~ 100%
13. Breath holding time (breath holding at the end of inspiration, inspiratory platform) (tip) 0-6 s (0% ~ 50% inspiratory time)
14. Sighing ventilation (sight) 0,1 / 100 ~ 5 / 100
(the tidal volume of sigh ventilation is 1.5-2 times the set value of tidal volume)
15. Suffocation ventilation off, 5 S-60 s
16. Maximum inspiratory flow rate ≥ 60 L / min
17. Pressure limit (adjustable pressure limit) 20 cmH2O ~ 100 cmH2O
18. Maximum limit pressure (safety relief pressure) ≤ 125 cmH2O
19. When manual ventilation, the output gas flow is more than or equal to 25 L / min
20. The maximum output pressure of atomizer gas is ≤ 0.2 MPa, and the maximum output flow is ≥ 8 L / min
Monitoring parameters
1. Frequency (freq) 0 / min ~ 100 / min
2. Tidal volume (VT) 0 ml ~ 3000 ml
3. Minute ventilation (MV) 0 L / min ~ 99 L / min
4. Respiratory pressure monitoring 0 cmH2O ~ 100 cmH2O
5. Dynamic lung compliance monitoring 1 ml / cmH2O ~ 1000 ml / cmH2O
6. Inhaled oxygen concentration 15% ~ 100%
Multi parameter monitoring display
1. Spontaneous breathing tidal volume (vtspn)
2. Spontaneous breathing capacity (mvspn)
3. Spontaneous breathing rate (fspn)
4. Total frequency (ftot)
5. Inhaled tidal volume (VTI)
6. Spontaneous breathing lung compliance (CSPN)
7. Mean pressure (pmean)
8. Platform pressure (pplat)
9. Shallow rapid breathing index (RSBI)
6、 Graphic display
1. Airway pressure time waveform (P-T ^)
2. Flow time waveform (F-T)
3. Either co2-t or V-T can be displayed
4. Pressure capacity ring (P-V), flow capacity ring (F-V)
5. Multi parameter display window switching
7、 Alarm and protection
1. AC power failure alarm
2. Voltage under voltage alarm of internal standby power supply
3. Air cut-off (no tidal volume) alarm
4. High (low) tidal volume alarm
5. High (low) ventilation alarm
6. Alarm for high (low) end tidal carbon dioxide [optional]
7. High (low) respiratory rate alarm
8. Alarm for high (low) end call positive pressure
9. High (low) airway pressure alarm
10. Pressure limit
11. High (low) oxygen concentration alarm
12. Suffocation alarm
13. Continuous pressure alarm
14. Low air (oxygen) supply pressure alarm
15. Fan fault alarm
16. Pressure safety relief valve ≤ 125cmh2o