110V 115V 120Vac Pure Sine Wave No Break UPS Poewr Supply
1: UPS with Single Phase 110V/115V/120Vac Input/Output
2: Eaton UPS Tech, 0.9 Output Power Factor
3: UPS Specially design for south amarican markets
4: China high quality UPS with digital LCD Screen
5: 120Vac UPS, 110Vac UPS, 115Vac UPS, Single Phase UPS, 1 Phase UPS, China UPS
UPS Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom^
UPS Key Features
1. Output power factor 0.9, offering more stronger load capability;
2. Online double conversion with DSP control
With excellent performance and comprehensive protections for load and UPS;
3. Self-diagnosis when UPS start up
4. Wide input range, support kinds of generator
5. Battery configuration flexible, 1KVA-24/36V, 2Kva-48/72/96V, 3Kva-72/96V etc.
6. Cold start(DC power on)
7. ECO function, Economic function (Optional)
8. Compact design and less noise
9. Lightening and Surge protection 1050J
10. Fan speed varies according to load automatically
11. Smart RS232 (USB, Dry contact, SNMP card optional)
12. Manual bypass (optional)
Model | K1K | K2K | K3K | K4K | K6K | K8K | K10K | |||
Capacity | Kva/Kw | 1Kva/0.9Kw | 2Kva/1.8Kw | 3Kva/2.7Kw | 4Kva/3.2Kw | 6Kva/5.4Kw | 8Kva/6.4Kw | 10Kva/8Kw | ||
Input | Voltage Range | 60-138VAC | ||||||||
Frequency range | 45-55Hz at 50Hz/55-65Hz at 60Hz(auto-detect) | |||||||||
phase | 1:1phase ,L+N+G | |||||||||
Current THDI | <6%(100%nonlinear load) | |||||||||
Power Factor | ≥0.99 | |||||||||
Generate Input | Support | |||||||||
Output | Voltage | 110//115/120/127Vac | ||||||||
Power Factor | 0.9 (0.8 Optional) | 0.8 | ||||||||
Voltage regulation | ± 2% | |||||||||
Frequency (Line Model) | 46-54Hz at 50Hz/56-64Hz at 60Hz | |||||||||
Frequency | 50/60Hz ± 0.02Hz | |||||||||
(Battery Mode) | ||||||||||
Current Crest Ratio | 3:01 | |||||||||
Harmonic Distortion | ≤3% THD(Liner Load) | |||||||||
≤5% THD(Non-Liner Load) | ||||||||||
Output waveform | Pure Sine wave | |||||||||
Outlet | Sockets(Optional) | Terminals | ||||||||
Overload Capacity | 105% | |||||||||
Efficiency | AC Mode | Full Load≥89% | ||||||||
Battery Mode | Full Load≥86% | |||||||||
ECO Mode | Full Load≥95% | |||||||||
Battery | Battery Type | Sealed, lead-acid, maintenance-free standard model: 12V/7AH or 9AH inbuilt long run model: battery external, capacity optional | ||||||||
Back Time | Standard unit: 7-12mins; | |||||||||
Long-run unit: depends on external battery | ||||||||||
Recharge Time (to 90%) | 5 Hours | |||||||||
Charge Current (standard unit) | 1.0A/2.0A | |||||||||
Charge Current (long run unit) | 4.0A/8.0A | |||||||||
Rated DC Voltage | 24/36vdc | 48/72/96vdc | 72/96vdc | 192vdc | 192vdc | 240vdc | 240vdc | |||
Protect | Over-Voltage/Over-current/Low-voltage | |||||||||
Battery Socket | Anderson like Power Pole Modular Connectors | |||||||||
Transfer Time | Mains←→Battery | 0ms | ||||||||
Mains←→Bypass | ||||||||||
Optional Features | Economic Mode | Support | ||||||||
(ECO Mode) | ||||||||||
Indicator | LCD Version (with LED) | Load/Battery/Input/Output/Operating Mode Information etc. | ||||||||
Audible Alarm | Battery Mode | Sounding every 4 seconds | ||||||||
Low Frequency | Sounding every second | |||||||||
Overload | Sounding twice every second | |||||||||
Fault | Continuously Sounding | |||||||||
Physical | Operating Environment | 0-40°C | ||||||||
Relative Humidity | 0-90%(non-condensing) | |||||||||
Altitude | ||||||||||
Noise Level | <55db at 1 Meter | |||||||||
Interface | Smart RS-232;USB,Dry contact board, SNMP (independent to RS232) |