Coated Fabric Air Permeability Tester Lab Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Medical Adhesive Tape Water Vapor Permeability Test Apparatus
Permeate Of Carbon Paper Layer In Fuel Cell Gurley Standard Air Permeability Testing Machine
Selective Transmittance Test Of Polymer Separation Membrane Gas Permeability Testing Machine
Peeling Strength Test Of Temperature Control Coating Micro Peeling Lab Testing Machine
Sliding Property Of Syringe Cartridge Stopper UTM Servo Auto Tensile Tester
Auto Servo Tensile Tester Opening Force Of Aluminum Plastic Combination Cover Of Penicillin Bottle
Coated Fabric Air Permeability Tester Lab Testing Machine
Product Detail
Application:
Based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Coated Fabric Air Permeability Tester Lab Testing MachineMembrane
Features:
Ÿ Vacuum differential pressure method
Ÿ Own technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Coated Fabric Air Permeability Tester Lab Testing Machine
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact