Professional Rohs xrf spectrometer for metal analysis
USD $10,000 - $10,000 /Set
Min.Order:1 Set
Hongjing Test Instrument Co., Ltd.
Application field
X-ray fluorescence spectrometer is an economical, practical and easy to operate X-ray fluorescence spectrometer; (RoHS analysis, halogen analysis) for lead (Pb), mercury (Hg), cadmium (Cd), chromium (Cr), bromine (Br) Elements such as chlorine (Cl) have good detection limits and precision. Comprehensive application of FP method, neural network method, empirical coefficient method, basic parameter method analysis software. It can fully meet the relevant control requirements of RoHS/WEEE/EN71 standard/ELV directive. The well-designed open working curve function is especially suitable for multi-material factory process control.
Applicable to: ROHS analysis of hardware, connectors, electronics, electrical, connectors, electroplating, PCB, plastic, leather, shoe materials, etc.
Product Features
1. Rapid elemental analysis from sulfur (S) to uranium (U);
2. Detection sensitivity is 0.01% to 100%;
3. The measurement time is short, and each measurement takes only 60-200 seconds.
4, 5 million pixel color CCD system for sample image observation.
5, there are a variety of collimators and filters to choose from, 5 sets of collimators and 4 sets of filters combined with electric automatic switching, to meet the application of various material testing methods.
6, electric refrigeration Si-Pin detector, improve measurement stability, improve the accuracy of analysis, no consumables.
7, mechanical structure is simple and reliable
8. International leading qualitative and quantitative analysis algorithms: FP basic algorithm, empirical coefficient method, neural network method, basic parameter method;
9. Fully enclosed metal chassis and anti-leakage protection switch design to better protect the personal safety of operators. Pipeline-type appearance,
beautiful appearance, large internal sample space of the instrument, excellent internal ventilation, and effective shielding of electromagnetic interference
10. Leading ultra-short optical path design, air-cooled X-ray tube is equipped with a unique light pipe management program, better heat dissipation, good heat dissipation system, more long-term use of the instrument, and effective extension of X-ray Tube life
11. Top-up type: It can meet the testing requirements of various shape samples, accurate sample imaging collimation system, and achieve accurate spot measurement of samples.
12,Automatic line recognition, multi-element simultaneous qualitative and quantitative analysis, allowing users to easily understand the composition of analytical samples, and set up automatic safety protection switches to ensure the safe use of users.
Host technical configuration instructions
1.Instrument working power: AC 220V ± 5V
2. Working environment temperature and humidity Working temperature: 15-30 ℃; Relative humidity: ≤80%; (non-condensing)
3.Host weight: 45Kg
4.Outline dimensions of the instrument: 600mm × 460mm × 380mm
5.Instrument sample bin size: 460mm × 300mm × 120mm
6.Minimum light spot: 0.5mm
7.Analyzable element range: Al-U, with ROHS and halogen, metal composition analysis
8.Minimum detection limit: Cd / Cr / Hg / Br≤1ppm, Pb≤2ppm Cl≤15
9.Measurement time: 60-300 seconds (adjusted by software)
10. Detector A new generation of Si-Pin detector produced in the United States; best resolution: 139 ± 5eV
11. X-ray tube: special energy spectrometer X-ray tube Max. Power 50W (50KV, 1mA)
12. High-voltage power supply: American high-voltage power supply: maximum power 50W (50KV, 1mA)
13.Rated power: 150W
14. Filter / collimator: 24 kinds of composite filter combinations, 0.2, 0.5, 1, 2, 6, 8mm, six collimators automatically switch.
15. Analysis software system: Energy dispersive X-ray fluorescence analysis system software Configure real-time online technical support.
16. Computer host configuration: high-end commercial Lenovo brand computer with 4GB memory / 500G hard disk / display 19 ’LCD Monitor
17. Printer: HP color inkjet printer (up to A4)
System standards and other
1.Ag standard sample
2.Plastic standard EU ERM-EC681M standard
3. Sample cups 2 sample cups (reusable)
4, Mylar film Test film roll
Input voltage:AC 220V±5% | |
Test object: | Powder, solid, liquid |
High voltage generator: | |
Input voltage | 24VDC±10% |
Output voltage | 0-50kV |
Output current | 0-1.0mA |
Output accuracy | 0.01% |
X-ray tube: | |
X-ray tube target | W target, Rh, Mo, Ag, Cr target optional |
X-ray tube window | Be window |
Electrical parameters | 50W,4-50kV,0-1.0mA |
Cold way | Silicone cooling |
Service life | More than 15,000 hours |
Detector: | |
examination range | Sulfur (S)-uranium (U) |
Resolution | 139±5eV |
Probe window | Beryllium window,Window area: 25mm2 |
Spectral processing system | |
Processor type | Fully digital DP5 |
Number of spectral channels | 2048 chanels |
Counting rate | 1000-8000cps |
Instrument appearance and sample chamber size | |
External dimensions (mm) | (length × width × height):600 mm ×460 mm×380mm |
Sample chamber test sample maximum size | 460 mm ×300 mm×120mm |
Sample stage carrying weight | ≤10kg |
Sample stage control method | Fixed sample stage |
Element minimum detection limit | Cd/Cr/Hg/Br≤2ppm,Pb≤2ppm Cl≤15ppm |
1. Are your company a trading one or a factory?
Factory ,13years focusing on test instruments field,3 years exporting experience.Our factory is in Dongguan, Guangdong, China
2. After an order is placed, when to deliver?
Usually about 15 working days, if we have finished products, we can arrange delivery within 3 working days.
Please note that our production lead time depends on the specific project and the number of projects.
3. What about the warranty with after - sales services?
12 months warranty.
After the warranty, the professional after-sales service team will provide comprehensive technical support to help customers solve problems encountered when using our products, and promptly handle customer problems and complaints.
4. What about the services and product' quality?
Service: ,Design service,Buyer lable service.
Quality: Each instruments must be carried out 100% quality examination and test, the finished products must through a third party calibration institutions before shipping and delivery goods.