FCC certification thermal abuse test chamber with good price
FCC certification thermal abuse test chamber with good price
FCC certification thermal abuse test chamber with good price
FCC certification thermal abuse test chamber with good price
FCC certification thermal abuse test chamber with good price
FCC certification thermal abuse test chamber with good price

FCC certification thermal abuse test chamber with good price

USD $5,000 - $15,000 /Set

Min.Order:1 Set

Supply Ability:
1000 Set / Sets per Month
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Hongjin
Place of Origin:
Guangdong, China
Model Number:
HY-TS-80A
Power:
Electronic

Hongjing Test Instrument Co., Ltd.

Credit Member 4 years
Business Type: Distributor/Wholesaler
Main Products: Testing Equipment , , ,

Product Details

Product overview

The three box type cold and heat shock test box is designed and manufactured according to the requirements of the user. It is suitable for high and low temperature impact test and storage and test in high temperature or low temperature environment for the whole machine and parts of aviation, aviation, military, naval, electrical, electronic and other products. In order to evaluate the test behavior of the whole machine (or component), electrical apparatus, instrument, material, coating, coating and so on, the user will test the climate and environment accordingly.

 

Product features

The equipment is divided into three parts, which are high temperature box, low temperature box and test box. The unique structure of heat break and the effect of heat storage and cold storage are collected. The cold and hot air road switching mode will be applied to the test area to realize the purpose of the cold and heat shock test.

Using the most advanced measuring device, the controller adopts the man-machine interface controller of large color liquid crystal touch control dialogue LCD. It is easy to operate, easy to learn, stable and reliable. In English, complete system operation condition, 

It can independently set the functions of three different conditions, such as high temperature, low temperature and cold and heat shock. When the cold and heat shock conditions are carried out, two slots or three grooves and cold and hot punching can be selected to carry out the function of the impact of the high and low temperature testing machine. It has fully automatic, high precision system loop, any machine parts movement, P.L.C locking process, P.I.D automatic calculation control, and high temperature control precision.

FCC certification thermal abuse test chamber with good price

Conversion method
The test sample is placed in the test chamber, and the high-pressure cylinder is used to open and close the damper, and the hot and cold air is quickly blown into the test slot according to the action, thereby achieving the purpose of rapid temperature change. Balanced Temperature Control System (TBHC) + Special Design Air Supply Cycle

 

Material
a) Inner box: SUS304 stainless steel plate.
b) Outer box: Cold-rolled steel plate, pickling phosphating surface, electrostatic spray anti-rust (or stainless steel plate)
c) Basket: SUS316 stainless steel plate.
d) Insulation: double protection of rigid polyurethane foam + aluminum silicate insulation cotton.
e) Damper seal: high and low temperature resistant silicone rubber seals.

 

Box door
a) Test the door with a single door, open the door and open the front.
b) Two high-low temperature silicone rubber sealing strips and anti-condensation electric heating device for window frame/door frame.
c) With observation window W250xH320mm3 layer vacuum layer, box lamp PL lamp 11W illumination lamp.

 

Technical Parameters

Test temperatureHigh temperature impact range: 60 ° C ~ +150 ° C
Low temperature impact range: -10 °C ~ -40 °C
Conversion timeWithin 10 seconds
High temperature slotRT (normal temperature) ~ +180 °C
Heating timeAbout 30 minutes
Low temperature slotRT (normal temperature) ~ -65 °C
Pre-cooling timeAbout 80 minutes
Resolution0.1 ° C
Control accuracy±0.5°C
Temperature deviation±2.0°C
LoadNo load (if power supply load test is required, power is required)
Test restrictionsThis equipment prohibits the testing and storage of flammable, explosive, corrosive and other items (if the test needs to be explained in advance)
temperature recovery time5 minutes
temperature exposure timeHigh temperature zone, 30 minutes each in low temperature zone

 

FCC certification thermal abuse test chamber with good priceFCC certification thermal abuse test chamber with good price

 

 

FCC certification thermal abuse test chamber with good price

Packing

FCC certification thermal abuse test chamber with good price

Company Information

FCC certification thermal abuse test chamber with good price

Contact Supplier

Mobile
12178253216

You May Like

New Products

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~