lab testing machine and humidity tester temperature walk in chamber
USD $14,500 - $15,000 /Set
Min.Order:1 Set
Hongjing Test Instrument Co., Ltd.
manufacturers climatic chamber walk in humidity test equipment
Hot sale stability climatic climate temperature humidity test chamber
factory direct sale constant climatic test temperature and humidity measurement stability chamber
Hot selling temperature and humidity test stability walk in tester chamber
industry testing room walk in climatic walk-in temperature and humidity test chamber
rubber/plastic industry climatic temperature and chamber walk in humidity test equipment
Temperature chamber application
The simulated products are tested under the combination of temperature and humidity in the climatic environment (high and low temperature operation & storage, temperature cycle, high temperature and high humidity, low temperature and low humidity, condensation test, etc.) to check whether the adaptability and characteristics of the product itself change.
Must meet the requirements of international standards (IEC, JIS, GB, MIL...) to achieve international measurement procedure consistency (including test procedures, conditions, methods)
Test limit
This test equipment is suitable for:
Electrical, electronic products, components, components and materials are stored in high and low temperature environments
Adaptability tests for storage, transportation and use.
This test equipment is prohibited:
Testing or storage of easy fire, explosive, volatile materials
Testing or storage of corrosive substance samples
Testing or storage of biological samples
Testing or storage of samples of strong electromagnetic emission sources
Volume, size and weight
Size(cm) | HJ-6 | HJ-8 | HJ-12 | HJ-16 | HJ-20 | HJ-24 | HJ-28 |
Inner box (D*H*W) | 200*200*150 | 200*200*200 | 200*200*300 | 200*200*400 | 200*200*500 | 200*200*600 | 200*200*700 |
Outer box (D*H*W) | 220*250*270 | 220*250*320 | 220*250*420 | 220*250*520 | 220*250*620 | 220*250*720 | 220*250*720 |
Performance | |
Test environmental conditions | The ambient temperature is +25 ° C, the relative humidity is ≤ 85%, and there is no sample in the test chamber. |
High temperature range | 85°C(150°C) |
Low temperature range | A: +25 °C B:0°C C:-20°C :-40°C E:-60°C F:-70°C) |
Humidity range | 30-80%(Customize 10% - 98%) |
Temperature fluctuation | ±0.5°C |
Temperature distribution accuracy | ±2.0°C |
Humidity fluctuation | ±5% R.H. (damp heat only) |
Humidity distribution accuracy | ±5.0%. (damp heat only) |
Load situation | The test space is no more than three-quarters of the total space and there is no heat. |
testing method | GB/T 5170.2-1996 temperature test equipment |
GB/T 5170.5-1996 Damp heat test equipment (damp heat type only) |