100L Constant Temperature and Humidity Test chamber
USD $4,000 - $8,000 /Set
Min.Order:1 Set
Shenzhen Bonad Instrument Co., Ltd.
1. Name Model | Temperature and humidity test chamber |
2. Application scope | A) this equipment is suitable for all kinds of electrical and electronic products and other products, parts and materials to carry out high and low temperature constant and gradual change, wet heat test and other environmental simulation reliability test. B) other uses may cause injuries and equipment damage! |
3. Limit sample | Test equipment prohibit: Inflammable, explosive, easy to volatile substances sample Corrosive substance sample Biological sample Strong electromagnetic emission source sample Radioactive material sample Poisonous material sample In the process of test or store may produce flammable, explosive, volatile, poisonous, corrosive and radioactive material sample |
4. Volume, size and weight | |
4.1. Volume | (100L) |
4.2. Inner box size | W(500)mm × H(500)mm × D(400)mm |
4.3. Outer box | W(750)mm × H(1580)mm × D(1500)mm |
4.4. Power | AC 220V 50/60HZ 4KW |
4.5. Sample shelves | 2 pieces |
5. Performance | |
5.1. Model | BND-HWS-100L |
5.2. Temperature range | -20℃ ~ +150℃(-40℃ ~ +150℃ optional) |
5.3. Total power | 4KW |
5.4. Weight | 200Kg |
5.5. Test environment conditions | Environment temperature +25℃, relative humidity≤85%, under the condition of no sample in the chamber |
5.6. Analytical precision | Temperature: ± 0.01 ℃; Humidity: ± 0.1% R.H |
5.7. Temperature fluctuation | ±0.2℃ |
5.8. Temperature uniformity | ≤2.0℃ |
5.9. Heating rate | 1℃~3℃/min(nonlinear and no-load) |
5.10. Cooling rate | 0.7~1℃/min(nonlinear and no-load) |
5.11. Humidity range | 20% ~ 98%RH |
5.12. Humidity fluctuation | ±2.0%R.H. |
5.13. Humidity deviation | ±2% |
5.14. Special function | Hot air blowing drying function, no condensation phenomenon |
5.15. Working noise
| ≤75dB ( A sound level, constant, 1 meter in front of the device) |
5.16. Meet the test method
| GB/T 10592-2008 Technical conditions for high and low temperature test chamber GB/T 2423.1-2001 Test A: low temperature test method GB/T 2423.2-2001 Test B: high temperature test method GJB/T 150.3-1986 High temperature test method GJB/T 150.4-1986 Low temperature test method IEC68-2-14 test method N: temperature changeGR63 test conditions of the customer can be met (see the figure below), and humidity can be controlled by slope Warm prompt: pay attention to in the above paragraph 6 times of temperature and humidity need to 5 ℃ 25 ~ 32% range Another chemical dehumidifier. |