Low price climate environmental walk-in chamber factory sales to Pakistan Russia Bangladesh
USD $4,000 - $21,000 /Set
Min.Order:1 Set
Zhonghow Test Equipment Co., Ltd.
Simulated Solar Radiation Xenon Lamp Weather Resistance Testing Chamber/Climate Testing Machine
Manufacture ipx1/ipx2/ipx3/ipx4/ipx5/ipx6 measure rain spray test chamber
Simulation Environment Sand Dust Resistance Test Chamber machines/equipments
High Efficiently Thermal Shock Chamber Cold Hot Impact Test /machines and equipments
Lab Equipment stainless steel Automobile tire ozone aging testing chamber
walk-in stability chamber / Environmental test chamber/ climatic chamber room
1. Description:
Programmable Constant Temperature Humidity Chamber is for testing capability of heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance, suitable for quality control of the industries of electron, electrical equipment, vehicle, metal, foodstuffs,
chemistry, building materials, luggage, adhesion tape, printing, packaging, etc.
2.Technical parameters:
environmental chamber/ Environmental test chamber/ climatic chamber
Constant Temperature Humidity Chamber
Model | DZTH-80 | DZTH-150 | DZTH-408 | DZTH-800 | DZTH-1000 | |
Size chamber | Studio Size(W*H*D)cm | 40*50*40 | 50*60*50 | 60*85*80 | 100*100*80 | 100*100*100 |
Machine Size(W*H*D)cm | 90*136*94 | 100*146*104 | 110*171*137 | 150*186*137 | 150*186*157 | |
| Control Methods | Balanced temperature humidity control system (BTHC) PID intelligent adjust | ||||
Temperature and Humidity Range | -70°C~150°C; 20%-98%R.H | |||||
Accuracy | ±0.5°C, ±2.5%RH | |||||
Resolution | ±0.01°C, ±0.1%R.H | |||||
Heating Rate | ≤3°C/min | |||||
Cooling Rate | Average 1°C/min | |||||
Internal Material | SUS#304 stainless steel | |||||
External Material | SUS#304 stainless steel or Antirust processing cold-rolled steel sheet(Spray) | |||||
Insulation Material | Superfine wool + polyurethane foam | |||||
Regulator | Cooling Mode | Mechanical binary refrigeration way | ||||
Compressor | Closed compressor (French Tecumseh or German Copeland ) | |||||
Refrigerant | R23/R404A | |||||
Condensing Way | Air-cooling and Water-cooling | |||||
Humidifier | Stainless steel humidifying tube | |||||
Airflow Way | Broadband-type forced air circulation | |||||
Controller | Operate Interfaces | Korea TEMI 880 LCD touch screen | ||||
Memory capacity | 120 groups, each program 100 segment | |||||
Input | PT100 or T thermocouple | |||||
Communicate Interface | RS-232 | |||||
Subsidiary function | Upper and lower alarm; self diagnosis ; alarm display(fault cause); time sequence protection (Automatic turn on or turn off ) | |||||
Water supply | Water supply | Circulating water supply | ||||
Water tank | Built-in hand type(30Kg capacity) | |||||
Water quality | resistance >500Ω.m | |||||
Standard Configuration | One observe window(Double hollow toughened glass);one test pattern D50mm(on the left); 2 layers sample frame; one floodlight(fluorescent lamp);one water feeding tank; | |||||
| Power leakage protection; Dry heating protection; Water protection Over-temperature protection switch; Temperature deviation alarm, Compressor Overpressure; overload; Water shortage; Phrase shortage, etc. |
3. Featurers:
Constant Temperature Humidity Chamber
1)The separation of humidifier circuit from electric circuit improves safety and protects the circuit against the leakage of water supply line.
2)Available in Chinese and English LCD touch screen, easy operation and program.
3)Able to display the relative date and information of the whole operating system in running mode, graphic display. precautions, maintenance and troubleshooting appear on the screen instantly.
4)The Sirocco fan motor provides greater cyclic airflow to avoid dead corner in the chamber so as to obtain an uniform distribution of temperature and humidity.
5)The system of heating up, heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure rate.
6)Water Supply adopts automatic watering System, Circulating water supply together with water filter.
4.Corresponding standard:
Programmable Constant Temperature Humidity Chamber
GB11158 Technical conditions for high-temperature testing box
GB10589-89 Technical conditions for low-temperature testing box
GB10592-89 Technical conditions for high and low temperature testing box
B/T10586-89 technical conditions for humidity testing chamber
GB/T2423.1-2001 Low-temperature testing methods
GB/T2423.2-2001 High-temperature testing methods
B/T2423.3-93 Testing Method for humidity Test Chamber
GB/T2423.4-93 Alternating hot and humid testing method
GB/T2423.22-2001temperature testing method
IEC60068-2-1.1990 low-temperature testing method
IEC60068-2-2.1974 high-temperature testing method
GJB150.3 high-temperature testing
GJB150.4 low-temperature testing
GJB150.9 humid testing
***why you can choose us Zonhow***
1. many years of sustained accumulation of R&D and technology
2. stable personnel team of experienced engineers,skilled workers and professional sales group
3. gain big part of global market by offering good and inexpensive equipments
4. fast delivery with Door-to-Door shipping service to save your time
5. save your budget and maintenance job
6. clients place order immediately after visiting our factory