3BH-C2/C4 AC220V 50/60HZ hydraulic solenoid valve coil with good quality
USD $10 - $20 /Piece
Min.Order:1 Piece
Fujian Zhenyuan Hydraulic Equipment Co., Ltd.
Mfb-90yc ac wet valve electromagnet for valve
A, use
The mfb-90yc electromagnet is suitable for the control circuit of dc 50Hz and voltage to 220V.As the dynamic component of the hydraulic electromagnetic directional valve.Can be equipped with Japan oil research type (YUKEN) 6, 10 - way connect the box threaded joint electromagnetic directional valve.
2. Normal working conditions of mfb-90yc ac wet valve electromagnet
Install in any direction.
The use of the environment should not be sufficient to corrode the metal and to destroy the insulating gas and dust.Otherwise, it may affect product life.
The working system of long - term working system and intermittent periodic duty is applicable to electromagnets.
The reasonable fluctuation range of the power supply voltage is 85%-110% (request for special request).
The enclosure protection class is IP65.
3. Main technical parameters of mfb-90yc ac power magnet
The operating frequency (T/h) of the total stroke consumption of the rated range of the rated output of the product
Ac wet valve electromagnet MFB12-90YC AC110V is greater than 90N 4mm or less than 9mm or 336w 21MPa 12000T/h
Ac wet valve electromagnet MFB12-90YC AC220V is greater than 90N 4mm or less than 9mm or 336w 21MPa 12000T/h
4. Mfz12-90yc ac wet valve electromagnet for use of attention matters
(1) the electromagnet adopts the socket which conforms to the ISO4400 standard.There are two specifications with the indicator light and no indicator light. You can choose according to the need.The voltage specification of the outlet with the indicator light shall be in accordance with the voltage specification of the electromagnet.
(2) manual push rod for electromagnet is used for manual control during commissioning or emergency situations.But when the system back pressure is higher, adjustment difficulties, please use the phillips screwdriver slowly push manual push rod, unfavorable use impact, so as not to damage the manual push rod and guide inner hole surface, electromagnet leak or position.
(3) when using an electromagnet in both directions, make sure that two electromagnets cannot be energized at the same time, so that the solenoid valve cannot work properly.
(4) there should be a flow protection device between the electrical control system and the electromagnet connection part, so as not to burn the electromagnet and your electric control element in the abnormal condition.
(5) when the power supply is ac, the mfbb-yc can be used to communicate the whole electromagnet, which is the same as MFZ12- YC, and can reduce the noise level of the system.
Collecting valve | Maintaining valve | |
Throttle valve | Relief valve | Solenoid directional valve |
Speed regulation valve | Pressure reducing valve | Manual reversing valve |
Diverter valve | Pressure valve | Check valve |
Flow valve | Cartridge valve | Hydraulic control one-way valve |
Collecting valve | Stop valve | Solenoid valve |
Pilot valve | Reverse check valve | Superposition valve |
Direct acting relief valve | Pilot check valve | Directional valve |
Pilot relief valve | Sequence valve | Pilot sequence valve |
Pilot reducing valve | Balance valve | Direct acting sequence valve |