Multi Parameter Patient Monitor with 15 Inch with Six Parameters
Multi Parameter Patient Monitor with 15 Inch with Six Parameters
Multi Parameter Patient Monitor with 15 Inch with Six Parameters
Multi Parameter Patient Monitor with 15 Inch with Six Parameters
Multi Parameter Patient Monitor with 15 Inch with Six Parameters

Multi Parameter Patient Monitor with 15 Inch with Six Parameters

Negotiable /Unit

Min.Order:1 Unit

Supply Ability:
500 Unit / Units per Month
Port:
Zhengzhou
Payment Terms:
T/T Other
Delivery Detail:
5 days

Quick Details View All >

Brand Name:
BENEMED
Place of Origin:
China
Model Number:
BenePM15
Type:
First-Aid Devices

BENEMED (HK) Industry Co. Limted

Business Type: Manufacturer
Main Products: Hematology Analyzer ,Urine analyzer ,Protein analyzer ,Chemistry analyzer ,Electrolyte analyzer ,OT products ,Patient monitor ,Ultrasound scanner

Product Details

Features: 

  1. Parameters: ECG, SPO2, NIBP, HR, TEMP, RESP

  2. Networkable with Central Monitoring System

  3. 720 hours trend data analysis

  4. Anti-ESU, anti-defibrillator; RA-LL impedance Respiration

  5. Compact design is convenient for mobile monitoring

  6. Efficient resistance to interference of defibrillator and electrosurgical cautery

  7. Real time S_T Segment analysis, pacemaker detection

  8. OxyCRG Dynamic View display, Trend Coexist display, etc

  9. 13 type Arrhythmic Analysis, Multi-Lead ECG Waveforms Display in Phase

  10. Built-in rechargeable battery with over 4 hour operating time

  11. Optional: Et-CO2, IBP, Recorder, touch screen

Specification:

ECG
Lead mode: 5 Leads(R,L,F,N,C or RA,LA,LL,RL,V)
Connection method:I,II,III,AVR,AVL,AVF,V
Lead Mode: 3 Leads (R,L,L or RA,LA,LL)
Connection method: I, II, III
Waveform: 2ch
Gain: 1/4, 1/2, 1, 2, AUTO
HR Range: Adult: 15~300bpm
             Neo/Ped: 15~350bpm
Accuracy: ±1% or ±1bpm, which great
Resolution: 1bpm
Sensitivity: >200(uVp-p)
Differential input impedance:≥5MΩ
ST segment Monitoring Range
Measure Range:-2.0~+2.0mV
Measure Accuracy: -0.8mV~+0.8mV

Heart rate
Measuring range: 0~350bpm
Accuracy: ±1bpm
Resolution: 1bpm
Sensitivity: >200UVp-p

Respiration
Method: Impedance between R-F(RA-LL)
Differential Input Impedance: >2.5MΩ
Measuring Impedance Range: 0.3~3.0 MΩ
Base line Impedance Range: 200~4000Ω
Bandwidth: 0.1~2.5Hz

NIBP
Method: Oscillometric
Mode: Manual/Auto
Measuring Interval in AUTO Mode: 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min)
Measuring Period in STAT Mode: 5 Min
Pulse Rate Range: 40~240bpm
Alarm Type: SYS, DIA, MEAN
Resolution
Pressure: 1mmHg
Accuracy: Maximum Mean error: 5mmHg
Maximum Standard deviation: 8mmHg

SPO2
Display: Number of SPO2,waveform of capacity,Pulse
Measuring range: 0~100%
Resolution: 1%
Accuracy: 70~100% (±2%)
Alarm system: Audio-visual alarm
Pulse rate range: 0~300bpm

TEMP
Channel: 2
Measuring and Alarm Range: 0~50ºC
Resolution:0.1ºC
Accuracy: 0.1ºC
Actualization interval: about 1 Second.
Average Time Constant:<10 Second.

System
Display system: 15 inch high-brightness color display
Network with central station
Power supply:AC100V~250V,50Hz/60Hz
Optional Parameter: IBP,EtCO2,Recorder,Touch Screen,Central Monitoring
Size: 340mm×310mm×150mm
Weight: 4.5 kg