Patent design /Bacterial Filtration Efficiency (BFE) Tester for N95 Mask Testing and Surgical Mask Testing
USD $56,000 - $59,000 /Set
Min.Order:1 Set
Guangzhou Biaoji Packaging Equipment Co., Ltd.
Mobile Atomizing Humidification And Disinfection Equipment,air sterilization equipment
EOResidual Tester | EtO Residual Analysis | Gas Chromatography for ASTM F2100
Mobile Atomizing Humidification And Disinfection Equipment GB-D100
Water Vapor Transmission Rate Testing Instrument For Plastic Packaging Proper
Highly Accurate Water Vapor Permeation Analyzer Using Infrared Sensor ASTM F1249
GB-XF1000 Bacterial Filtration Efficiency (BFE) Detector
Mask Bacterial Filtration Efficiency (BFE) Detector
Standards:
YY0469-2004,YY/T 0969-2013,ASTMF2100,ASTMF2101,EN14683
Function:
To test the meaterial/product tensile strength, extensibility at break, peel force, peeling strength and heat-sealing strength,tear, punch, compressed, bending, shearing
Application:
It is used to test the percentage of materials containing bacteria suspended particles at the specified flow rate. The dual gas path simultaneous comparison sampling method is used to improve the accuracy of sampling, which is suitable for the performance testing of bacterial filtration efficiency of medical surgical by metrological inspection departments, scientific research institutes, medical mask manufacturers and other relevant departments.
Techinical Parameter:
Key Specification |
Specification Range Resolution Accuracy |
A Route Sampling Flow |
28.3L/min 0.1L/min Within ± 2.5% |
B Route Sampling Flow |
28.3L/min 0.1L/min Within ±2.5% |
Spray Flow |
(8~10)L/min 0.1L/min Within ±2.5% |
Peristaltic Pump Flow |
(0.006~3.0)mL/min 0.001ml/min Within ±2.5% |
Negative Pressure of the Cabinet |
-50~-200pa |
Data Storage Ability |
>100000 sets |
Negative Chamber Flow Speed |
≥5m3/min |
Power Supply |
AC220V±10%, 50Hz |
Features:
1. Negative pressure experiment system to ensure the safety of operators;
2. Negative pressure cabinet with built-in peristaltic pump and A and B two-way six-stage Andersen;
3. The flow rate of the peristaltic pump can be set;
4. Dedicated microbial aerosol generator can set the volume of bacterial liquid spray flow, and the atomization effect is good;
5. Embedded high-speed industrial microcomputer control;
6.10.4-inch industrial-grade high-brightness color touch display;
7, USB interface, support U disk data transfer;
8. Built-in high-brightness lighting in the cabinet;
9. Built-in leakage protection switch to protect operator safety;
10. Insulation and flame retardant between inner and outer layers;
11. The front switch glass door is convenient for experimenters to observe and operate;
12. Detachable stand, the height of stand is adjustable;
13. Support and move dual-purpose casters.