High Quality Digital Medical Electrocardiograph 3 Channel ECG Machine
Negotiable /Unit
Min.Order:1 Unit
BENEMED (HK) Industry Co. Limted
12 Inch Big Screen Foldable Digital Hospital Electrocardiograph 12 Channel
Benemed Hotsale Digital Hospital Electrocardiograph 12 Channel ECG Machine
Portable Digital Hospital Electrocardiograph 3 Channel ECG Machine
Portable Digital Hospital Electrocardiograph 12 Channel Interpretive ECG Machine
Portable Digital Hospital Electrocardiograph 12 Channel Interpretive ECG Machine
Premium Hospital ECG Machine with 10.1 Inch Touch Screen Bm-ECG1212
Features:
Multiple printout format
CMRR of 100dB
Polarizing voltage of ±600mV
Low pass filter
Frenquency Response 0.05~150Hz
200 exams internal extended SD
Specification | ||
Display: | 7" TFT 480 X 800 liquid crystal display (LCD) | |
Lead: | Standard or Cabrera 12 leads, | |
Simultaneously 12 leads acquisition | ||
Sampling Rate & Quantization: | 1000samples/second/channel 3.125μV/LSB | |
Recovery time of defibrillator after discharge: | <10s | |
Frequency Response: | 0.05~150Hz(-3.0dB - +0.4dB)under 10Hz | |
Time Constant: | ≥3.2s | |
CMRR: | >100dB with filter, >89dB without filter | |
Input Circuit Current: | ≤ 0.1µV | |
Noise Level: | ≤15μVp-p | |
Polarization Voltage: | ±500mV | |
Minimum Detection Signal: | 20µV | |
Calibration Voltage: | 1mV± 2% | |
AC filter: 50Hz/60Hz, -20dB | ||
Filter: | EMG filter:25Hz/35Hz/45Hz/75Hz/100Hz, -3.0dB | |
Drift filter: 0.5Hz, -3.0dB | ||
Sensitivity: | 1.25, 2.5, 5, 10, 20,40mm/mV±2% | |
Paper Speed: | 5, 6.25, 10, 12.5, 25, 50mm/s±3% | |
Recording Mode: | Thermal paper printing | |
≥8 dot/mm(Vertical) | ||
Printing Resolution: | ≥40 dot/mm(Horizontal, 25mm/s) | |
≥20 dot/mm(Horizontal, 50mm/s) |
Environmental Conditions | |
Transportation: | Temperature: -20ºC~+55ºC |
Relative Humidity:25%~95% | |
Atmospheric Pressure:700hPa~1060hPa | |
Storage: | Temperature: -10ºC~+40ºC |
Relative Humidity:25%~80% | |
Atmospheric Pressure:700hPa~1060hPa | |
Operation: | Temperature: +5ºC~+40ºC |
Relative Humidity:25%~80% | |
Atmospheric Pressure:700hPa~1060hPa |
Safety Index | ||||
Input Circuit: | Floating, Defibrillation protection | |||
(use defibrillation ECG cables) | ||||
Patient Current Leakage: | <10μA | |||
Input Impedance: | DC signals≥50MΩ, AC signals≥2.5MΩ | |||
Safety: | IEC Class I, type CF, | |||
Power supply: | AC 100V~230V, 50Hz/60Hz, 75VA | |||
Rechargeable Li-battery: | 11.1V 1800mAh | |||
Exams | ||||
200 exams to be stored in memory for rell and deplication | ||||
Paper size | ||||
80mm*20m Roll type/Z-folding | ||||
Print out format | ||||
3/2 channel, 3/2+1 channale, | ||||
3/3 channel,3/3+1 channel | ||||
Dimension and Weight | ||||
Dimension: 285mm×200mm×50mm | ||||
Weight: 1.65KG |