Water Vapor Permeability Testing For Hygroscopic Method Of Medical Protective Clothing
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Ethylene Oxide Residue Of Sterilized Face Mask Gas Chromatography
Paper/ Battery Membrane Air Permeability Test Lab Gurley Method Test Apparatus
Tensile Breaking Strength Of Protective Mask Belt Lab Test UTM Servo Tensile Testing Machine
Building Materials Weighing Method Water Vapor Permeability Test Lab Testing Machine
Fracture Strength Of Elastic Band Of Respirator Universial Testing Machine ASTM
Food Desiccant Packaging Water Vapor Permeability Test Weighing Method Lab Testing Machine
Water Vapor Permeability Testing For Hygroscopic Method Of Medical Protective Clothing
Products Details
Application:
Based on the electrolytic sensor method and available for the water vapor permeability test of flexible films, sheeting and packages. It can test 3 specimens in one operation with independent results.
Films:
Plastic films, composite films and many others.
Packages:
Plastic packages.
Water Vapor Permeability Testing For Hygroscopic Method Of Medical Protective Clothing
Features:
— Electrolytic sensor method
— Own technology
— Film and package test
— 3 specimens test simultaneously and independently
— One-button test, test automatically in whole process
— Multiple test modes optional
— Data curves display
— Computer control
— Digital flow adjustment
— 3 Chambers with 3 temperature sensors
— Environment temperature and humidity sensor inside
— Chambers water bath technology
— Unit based on embedded system,24bit Δ-Σ AD
— Pressure, ppm water sensor and temperature overload protection
— Traceable reference film calibration
— Supports DSM system (DSM, lab data management system)
Water Vapor Permeability Testing For Hygroscopic Method Of Medical Protective Clothing
Technical indexes:
Test range: | |
Film | 0.001-52 g/m2·24h (Standard) |
0.01-1100 g/m2·24h (Optional) | |
Resolution | 0.001 g/m2·24h |
Package | (optional) |
0.0001~0.5 g/pkg·d | |
Resolution | 0.00001g/pkg·d |
Specimen amount | 3 specimens, independent |
Temperature range | 5C – 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH, standard condition 90%RH |
Humidity accuracy | ±1%RH |
Test area | 50 cm2 |
Specimen size | |
Film | size |
Thickness | less 5mm |
Package | |
Max size | D120mm * 400mm |
Carrier gas | 99.999% Nitrogen |
Carrier flow | 0~200 ml/min |
Gas interface | 1/8inch |