Integrated motor 0-1100RPM MODBUS communication
Integrated motor 0-1100RPM MODBUS communication
Integrated motor 0-1100RPM MODBUS communication
Integrated motor 0-1100RPM MODBUS communication
Integrated motor 0-1100RPM MODBUS communication
Integrated motor 0-1100RPM MODBUS communication

Integrated motor 0-1100RPM MODBUS communication

USD $93 - $154 /Unit

Min.Order:1 Unit

Supply Ability:
100000 Unit / Units per Month
Port:
FOB Ningbo
Payment Terms:
T/T Credit Card

Quick Details View All >

Brand Name:
Volcano Electric
Place of Origin:
Zhejiang, China
Model Number:
Custom

Ningbo Haofeng Magnet Technology Co., Ltd.

Business Type: Other
Main Products: motor

Product Details

Product Display

Integrated motor 0-1100RPM MODBUS communication

 

IEC #100/112220VAC (Customized DC 24/48/60/72/96V)

Rated output

KW2.253.755.5

Rated torque

N.m

21.49

35.8123.8811.9435.0217.51

Rated current

A8.5414.2314.2314.2320.8720.87

Rated speed

rpm100010001500300015003000
Peak torqueN.m64.46107.4471.6335.81105.0552.53

Maximum speed

rpm120012002000500020005000
Torque constantN.m/A2.522.521.680.841.680.84

Induced voltage constant

V/Krpm2052051276712767
Rotor inertiaKg.m^20.006410.00840.006410.00440.00840.00641

 

IEC #100/112380VAC (Customized DC 24/48/60/72/96V)

Rated output

KW2.253.755.5

Rated torque

N.m

21.49

35.8123.8811.9435.0217.51

Rated current

A4.908.178.178.1720.8711.98

Rated speed

rpm100010001500300015003000
Peak torqueN.m64.46107.4471.6335.81105.0552.53

Maximum speed

rpm120012002000500020005000
Torque constantN.m/A4.384.382.921.461.681.46

Induced voltage constant

V/Krpm355355205116205116
Rotor inertiaKg.m^20.006410.00840.006410.00440.00840.00641


Integrated motor 0-1100RPM MODBUS communication 

Integrated motor 0-1100RPM MODBUS communication

 

Integrated motor 0-1100RPM MODBUS communication

 

VIEW MORE PLS CONTACT US >>>

 

 

Other Products

Integrated motor 0-1100RPM MODBUS communication

Process Flow

Integrated motor 0-1100RPM MODBUS communication 

About Us

Integrated motor 0-1100RPM MODBUS communicationIntegrated motor 0-1100RPM MODBUS communication 

Packing&Transport

Integrated motor 0-1100RPM MODBUS communication

Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped. 

      What to do: Replace the fuse or reset the breaker.

 

     Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
     What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

 

     Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
     What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

 

      Likely cause: Controller may be defective.
      What to do: Verify voltage is coming out of the controller.

 

Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
     What to do: Verify that the motor is wired correctly.

 

     Likely cause: No output power from controller.
     What to do: Measure voltage coming from the controller.

 

     Likely cause: Motor is damaged and the armature is rubbing against the magnets.
     What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

 

Q:  Motor takes too long to accelerate,what to do?
A:  Likely cause: Motor controller not properly set.
     What to do: Adjust the acceleration trim pot of the controller.

 

     Likely cause: Brushes are worn.
     What to do: Verify brush length.

 

     Likely cause: Bearings may be defective.
     What to do: Inspect bearings. Noisy or rough bearings should be replaced.

 

Q:  Motor runs in the wrong direction,what to do?
A:  Likely cause: Incorrect wiring
     What to do: Interchange the two motor leads.

 

Q:  Motor runs OK but has a clicking noise,what to do?
A:  Likely cause: Suspect a burr on the commutator.
     What to do: Remove burr from commutator using a commutator stone.