250w 2800w 2kw 300 watt 300v 350w bldc hub motor controller
USD $300 - $900 /Unit
Min.Order:1 Unit
4 inch 3kw 36v 250w 350w 750w bldc hub motor and control 72v 3v
Custom 48v 1.5hp 1000w 40w 450w 48 volt 5kw brushless dc motor control for india e rickshaw
48v 1000w 1200w 1500w 2000w high torque brushless bldc motor for india market
48v 2000w 5000w 500w 2kw 3kw 5kw bldc boat motor control 48v
5hp 50w 4kw 48v 500 watt 500w high torqu bldc submers motor kit
80mm 72v 1000w 2500w 750w 800w 850 w 750 60 watt 600a bldc ceiling fan motor kit control
Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
KW | V | A | RPM | Nm | % | dB | ||
VOL- IEC90S2250-2P | 2.25 | 220 ac | 6.42 | 3000 | 7.16 | 92 | 62 | IP 54 |
VOL- IEC100S2250-4P | 2.25 | 220 ac | 6.42 | 1500 | 14.33 | 92 | 62 | IP 54 |
VOL- IEC112S2250-6P | 2.25 | 220 ac | 6.42 | 1000 | 21.48 | 92 | 62 | IP 54 |
VOL- IEC112S3750-2P | 3.75 | 220 ac | 10.70 | 3000 | 11.94 | 92.5 | 62 | IP 54 |
VOL- IEC112S3750-4P | 3.75 | 220 ac | 10.70 | 1500 | 23.88 | 92.5 | 62 | IP 54 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.