Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
KW | V | A | RPM | Nm | % | dB | ||
VOL-BL300A12 | 0.3 | 12 | 27.17 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A24 | 0.3 | 24 | 13.59 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A48 | 0.3 | 48 | 6.79 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A72 | 0.3 | 72 | 4.53 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A110 | 0.3 | 110 ac | 1.71 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A220 | 0.3 | 220 ac | 0.86 | 1500 | 1.91 | 92 | 62 | IP 54 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.
You May Like
- IEC 1/4 HP permanent-magnet synchronous brushless DC motor
- 3.58Nm 1000rpm IEC PMSM fan Brushless DC motor for air cooler
- IEC 3HP 3 phase synchronous motor PMSM motor China
- IEC 2HP High torque synchronous motor PMSM motor from china
- IEC 200W 110V Permanent Magnet Synchronous Motor Electric Motor
- IEC 1/2HP 220v synchronous motor PMSM AC motor
- IEC 1/4HP 1000rpm 220v 200w permanent magnet synchronous dc motor
- IEC 5HP 3750W 220v 3 phases synchronous motor PMSM motor China
- IEC 1HP 750W 220v synchronous motor PMSM motor China
- IEC 5HP 220v 3750W 3 phases synchronous motor PMSM motor China
Popular Searches
Find Similar Products By Category
You May Like
- 220Vac 1/2HP PMSM brushless DC motor with IEC standard
- IEC 2HP 1500W 220v 3 phases synchronous motor PMSM motor from china
- IEC 3HP 3 phase 220v PMSM ac motor price
- IEC 71S size 1000rpm 187w PMSM electric Brushless DC motor
- IEC 200v PMSM AC motor
- IEC 3HP 220v electric motor PMSM ac motor
- 110Vac Permanent Magnet Synchronous Motor 0.2KW
- IEC 1HP 750w 3000rpm 220v synchronous motor
- IEC 1/2HP 220v 375W 1500rpm synchronous PMSM motor for electric vehicle
- IEC 2HP High torque synchronous motor PMSM ac motor
- Voltage 220Vac 187w Electric PMSM motor with brushless
- IEC 1/2HP PMSM brushless dc motor from china
- 200watts 2000w driver board sew direct drive washing machine stator brushless dc motor and esc
- 3000rpm 110v IEC standard 3 phases permanent-magnet synchronous brushless DC motor
- 2hp 1500rpm 4.3A IEC standard PMSM dc brushless synchronous motor