48v 2500w 220v 4kw ip68 single phase bike imanes permanentes fan electric brushless dc motor
USD $220 - $300 /Unit
Min.Order:1 Unit
waterproof 110Vac 1500RPM 5000watts permanent magnet brushless dc motor
7KW 1500RPM 220Vac energy saving powerful motor permanent magnet brushless dc motor
high torque 380Vac 1500RPM 7KW permanent magnet brushless dc motor for industrial machine
4000w 110V 1500rpm Industrial leader dc brushless servo motor
Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
KW | V | A | RPM | Nm | % | dB | ||
VOL-BL3K5A72 | 3.5 | 72 | 51.71 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5A110 | 3.5 | 110 ac | 19.54 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5A220 | 3.5 | 220 ac | 9.77 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5A380 | 3.5 | 380 ac | 5.66 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5B72 | 3.5 | 72 | 51.71 | 3000 | 11.14 | 94 | 62 | IP 54 |
VOL-BL3K5B110 | 3.5 | 110 ac | 19.54 | 3000 | 11.14 | 94 | 62 | IP 54 |
VOL-BL3K5B220 | 3.5 | 220 ac | 9.77 | 3000 | 11.14 | 94 | 62 | IP 54 |
VOL-BL3K5B380 | 3.5 | 380 ac | 5.66 | 3000 | 11.14 | 94 | 62 | IP 54 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.