ip68 1500rpm 3000rpm 500w 0.9kw 1hp 12v 22v pamb single phase synchronous brushless dc motor
USD $200 - $480 /Unit
Min.Order:1 Unit
4kw 200 watt marathon electric rotor generator magnetic brushless dc motor for sale
1hp electric air conditioner fan explosion proof perendev magnetic wiper bicycle brushless dc motor
Customized HFM054 1050rpm 2200w 380V ac power waterproof brushless dc motor
48v 2000w lawn mower electric forklift controller differential sensorless brushless dc motor
Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
KW | V | A | RPM | Nm | % | dB | ||
VOL-BL3K5A72 | 3.5 | 72 | 51.71 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5A110 | 3.5 | 110 ac | 19.54 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5A220 | 3.5 | 220 ac | 9.77 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5A380 | 3.5 | 380 ac | 5.66 | 1500 | 22.28 | 94 | 62 | IP 54 |
VOL-BL3K5B72 | 3.5 | 72 | 51.71 | 3000 | 11.14 | 94 | 62 | IP 54 |
VOL-BL3K5B110 | 3.5 | 110 ac | 19.54 | 3000 | 11.14 | 94 | 62 | IP 54 |
VOL-BL3K5B220 | 3.5 | 220 ac | 9.77 | 3000 | 11.14 | 94 | 62 | IP 54 |
VOL-BL3K5B380 | 3.5 | 380 ac | 5.66 | 3000 | 11.14 | 94 | 62 | IP 54 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.