IP54 375W 1500rpm 18.5A IE 3 BLDC motor used for automatic gate
USD $1 - $250 /Unit
Min.Order:1 Unit
300 watt 12v 48v 5kw 2kw 1500rpm 3000rpm 6000 rpm custom made dc brushless gear motor for car
Class F low voltage high efficiency 12v 375w 1500-3000RPM brushless dc motor
IE 4 waterproof 3000rpm 375w 48v 8.5A brushless dc motor with gearbox
375w 12v 24v 36v 48v 72v 3000rpm waterproof brushless dc motor
Motor type | Output Power | Voltage | Load | Speed | Rated Torque | Efficiency | Noise | IP Class |
KW | V | A | RPM | Nm | % | dB | ||
VOL-BL300A12 | 0.3 | 12 | 27.17 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A24 | 0.3 | 24 | 13.59 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A48 | 0.3 | 48 | 6.79 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A72 | 0.3 | 72 | 4.53 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A110 | 0.3 | 110 ac | 1.71 | 1500 | 1.91 | 92 | 62 | IP 54 |
VOL-BL300A220 | 0.3 | 220 ac | 0.86 | 1500 | 1.91 | 92 | 62 | IP 54 |
VIEW MORE PLS CONTACT US >>>
Q:Motor has been running then fails to start,what to do?
A:Likely cause: Fuse or circuit breaker is tripped.
What to do: Replace the fuse or reset the breaker.
Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.
Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.
Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.
Q: On initial installation, motor fails to start up,what to do?
A: Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.
Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.
Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.
Q: Motor takes too long to accelerate,what to do?
A: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.
Likely cause: Brushes are worn.
What to do: Verify brush length.
Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.
Q: Motor runs in the wrong direction,what to do?
A: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.
Q: Motor runs OK but has a clicking noise,what to do?
A: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.