Medical Protective Clothing Fabric Materials Water Vapor Permeability Test WVTR Lab Pharma Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
High Pressure Of Gas Separation Membrane Gas Permeability Testing Machine Customized
Differential Pressure Separation Membrane Gas Permeate Testing Machine Lab Test Equipment
Differential Pressure Test Method Separation Membrane Gas Selective Testing Machine ASTM
Lithium Battery Separator Membrane Performance Test ASTM Gurley Method
Moisture Transmittance Test Water Vapor Permeability Test Machine Medical Clothing Fabric
Science Researching Materials Oxygen Permeability Test Lab Testing Machine ASTM 3985
Medical Protective Clothing Fabric Materials Water Vapor Permeability Test WVTR Lab Pharma Testing Machine
Product Details
Application:
Based on the humidity sensor detection method and available for the water vapor permeability test of heat exchange membranes, nonwoven fabrics and flexible barrier materials.
Medical Protective Clothing Fabric Materials Water Vapor Permeability Test WVTR Lab Pharma Testing Machine
Features:
features | Weighing method |
Dual weighing modules, own technology | |
18 specimens, continuously test | |
One-button test, test automatically in whole process | |
Multiple test modes optional | |
Temperature and humidity auto control | |
Data curves display | |
Computer control | |
Environment temperature and humidity sensor inside | |
Unit based on embedded system,24bit Δ-Σ AD | |
Traceable reference film calibration | |
Supports DSM system (DSM, lab data management system) |
Principles:
The specimen is clamped between the upper and lower chamber, the upper chamber is high humidity side, and the other side of specimen, lower chamber is purged by a stream of dry gas, due to the effect of water concentration gradient at two sides of the specimen, water molecules will permeate through the specimen into the dry gas side, penetrated water molecules will be carried to the relative humidity sensor which generates the proportional signal, so water vapor transmission rate will be obtained by calculating the sensor signal.
Medical Protective Clothing Fabric Materials Water Vapor Permeability Test WVTR Lab Pharma Testing Machine
Technical indexes:
Test range | 5 - 6500 g/m2·24h (Standard) |
Resolution | 0.001 g/m2·24h |
Specimen amount | 1 specimen |
Temperature range | 5C–95C |
Temperature accuracy | ±0.1C |
Humidity range | 100%RH (Standard) |
Humidity accuracy | ±1%RH |
Test area | 38 cm2 (Standard) |
Specimen size | >=150mm * 94mm |
Thickness | less 3mm |
Carrier gas | Dry Air, or 99.999% Nitrogen |
Carrier flow | 0~200 ml/min |
Gas interface | 1/8inch |
Products Catalog
What we can provide
Packing
Export Areas