Gas Permeate Test For Proton Exchange Membrane/ ERV/ HRV Gas Permeability Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Plastic Film Shrinkage Testing Machine Heat/ Cold Shrink Rate Lab Test
Auto Servo Tensile Testing Machine UTM Puncture/ Tensile/ Compression/ Peeling Tester ASTM Standard
Flexible Packaging Film Dynamic/ Static Friction Coefficient Test COF With ASTM /ISO Standard
Gas Permeate Testing Machine Proton Exchange Membrane ISO & ASTM Standard Permeability Tester
Free Falling Dart Impart Testing Machine Method A & Method B Auto Impact Lab Tester
Gas Permeate Test For Proton Exchange Membrane/ ERV/ HRV Gas Permeability Testing Machine
Product Detail
Application:
Based on the differential pressure method, and is applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Gas Permeate Test For Proton Exchange Membrane/ ERV/ HRV Gas Permeability Testing Machine
Features:
Ÿ Vacuum differential pressure method
Ÿ Own technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Gas Permeate Test For Proton Exchange Membrane/ ERV/ HRV Gas Permeability Testing Machine
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |