Proton Exchange Membrane Gas Permeability Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Fuel Cel Exchange Separation Membrane Performance Test Gas/ Oxygen Permeability Testing Machine
Coefficient Of Permeate/ Diffusion Test For Plastic Membrane Lab Gas Permeability Tester
Liuthium Battery Separation Membrane Gurley Method Tesing Machine
Liuthium Battery Separation Membrane Gurley Method Tesing Machine
Separation Film Of Battery Perfomance Test Gas Permeability Test Gurley
High Precision Auto Thickness Testing Machine For Flexible Packaging
Proton Exchange Membrane Gas Permeability Testing Machine
Product Detail
Application:
GTR-7001 is based on the differential pressure method, and is applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Proton Exchange Membrane Gas Permeability Testing Machine
Features:
Ÿ Vacuum differential pressure method
Ÿ Own technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Proton Exchange Membrane Gas Permeability Testing Machine
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Dimension | 730mm * 510mm * 350mm |
Power supply | AC 220V 50Hz |
Net wt. | 63kg |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact