Standard Gurley Method Air Permeability Testing Machine
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Lithum Battery Separation Membrane Gas Permeability Testing Machine
ULtra High Pressure Air Permeability Testing Machine ASTM Standard
High Temperature Adhesive Strength Tester ASTM Packaging Tape Flexible Packages
Ethylene Oxide Extrusion Films Residue Tester Package Printing Gas Chromatography Detectors
Plastic Composite Films Gas Transmission Testing Machine Oxygen Permeability Values
Ceramic Coated Battery Diaphragm Micro Peeling Tester With Touch screen
Standard Gurley Method Air Permeability Testing Machine
Product Detail
Application:
GTR-7001 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Standard Gurley Method Air Permeability Testing Machine
Features:
Ÿ Vacuum differential pressure method
Ÿ Patent technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Standard Gurley Method Air Permeability Testing Machine
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Dimension | 730mm * 510mm * 350mm |
Power supply | AC 220V 50Hz |
Net wt. | 63kg |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact