Air Permeability Testing Machine Gurley Method Of Battery Separation Film
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Plastic Packages Cap Opening Force Testing Machine Torque Tester
Vacuum Leakage Test For Flexible Package Bubble Method Testing Machine
Impact Resistance Of Testing Equipment Polyethylene Blown Film Impact Tester
Industry Plastic Permeability Tester Lithium Ion Batteries Separator Renewable Energy
Water Vapor Permeability Testing Machine ASTM F1249 Shelf-life Extended Packaging Material Analyzer
Pharmaceutical Packaging Thermal Sealing Strength Tester Five Point Thermal Sealing Instrument
Air Permeability Testing Machine Gurley Method Of Battery Separation Film
Product Detail
Application:
GTR is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Air Permeability Testing Machine Gurley Method Of Battery Separation Film
Features:
Ÿ Vacuum differential pressure method
Ÿ Patent technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Air Permeability Testing Machine Gurley Method Of Battery Separation Film
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Dimension | 730mm * 510mm * 350mm |
Power supply | AC 220V 50Hz |
Net wt. | 63kg |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact