wholesale China factory 99.9% colorless Hydrogen chloride gas
Negotiable /Set
Min.Order:1 Set
Zibo Dijia Special Gas Co., Ltd.
Industrial grade hcl gas hydrogen chloride
Level: Industrial |
PURITY/%: ≥99% |
Packing: 880L/Y Type (New Size) |
Enterprise number: SDYH/Q-001 |
Weight: 500Kg |
Pressure: 4.2 Mpa (20℃) |
Valve: CGA330- 316LDiaphragm Valve |
Composition | Product specification | Inspection Equipment | Limit | |
Impurity 1*10-6(v/v) | Nitrogen | <=1300 | Helium Ion Chromatograph | 0.01 |
Hydrogen | <=1000 | Helium Ion Chromatograph | 0.01 | |
Carbon monoxide | <=600 | Helium Ion Chromatograph | 0.01 | |
Carbon dioxide | <=1500 | Helium Ion Chromatograph | 0.01 | |
Oxygen + Argon | <=3000 | Helium Ion Chromatograph | 0.01 | |
Hydrocarbon | <=2600 | Helium Ion Chromatograph | 0.01 | |
Water | <=5 | Online Micro Water Analyzer | 0.10 | |
Dew point/℃ | <-66 | Photoelectric Dew Point Meter | -85 |
Hydrogen Chloride Physical Constant
Molecular Formula | : HCL |
Molecular Weight | : 36.46 |
Gas Specific Weight (0℃, Air=1) | : 1.268 |
Specific Gravity Hydrometer(10℃, Water=1) | : 0.88 |
Critical Pressure | : 8.258MPa |
Critical Temperature | : 51.4℃ |
Critical Density | : 0.424g/cm3 |
Latent heat Of Evaporation | : 443.3Kj/Kg |
Gas Density(0℃,0.1MPa) | : 1.639g/dm3 |
Molar Volume | : 22.25L |
Gas Viscosity Measurement (20℃) | : 1.56c/o 10-5Pa S |
Constant-pressure Specific Heat(15℃,0.1MPa) | : Cp=0.812Kj/Kg K |
Constant-volume Specific Heat(15℃,0.1MPa) | : Cv=0.576Kj/Kg K |
1L Liquid(10℃)= | 540L Gas |
1Kg Liquid= | 613L Gas |
Latent Heat Of Melting | : 54.80Kj/Kg |
Atmospheric Boiling Point | : -85℃ |
(21℃,0.1MPa) | : 1.522g/dm3 |
Color | : Colorless |
Warranty | : 24 Months |
UN Number | : 1050 |
Liquid hydrogen chloride vapor pressure:
Temperature (℃) | -85.03 | -10 | 0 | 10 | 20 | 30 | 40 |
Pressure (Mpa) | 0.1 | 1.96 | 2.57 | 3.32 | 4.21 | 5.27 | 6.53 |
Density (g/cm3) | 1.191 | 0.962 | 0.924 | 0.881 | 0.831 | 0.772 | 0.697 |
Physical & Chemical Properties
Colorless, toxic, irritating, smothering, non-flammable gas: strong hygroscopic, after absorbing the moisture in the air, hydrochloric acid is generated, with strong corrosiveness.
Stored in cylinders in the form of liquefied gas, pressure (3-6MPa) is constant, and its value is related to temperature.
Inorganic compounds such as tin chloride, phosphorus trioxide, phosphorus bromide, and so on, and organic compounds such as paraffin, ethanol, ether, acetaldehyde, ketone, acid, ester, nitrite, cyano, etc. can be dissolved well in hydrogen chloride, and additional reaction can occur.
Pure liquid hydrogen chloride does not react with most metals. However, it reacts with alkali metals, aluminum, manganese, iron, copper, tin, lead and zinc and produces a protective film of chloride on its surface.
When water is present, it reacts with metal to form metal chloride and hydrogen gas.
Use & Storage
The storage room for hydrogen chloride cylinder should be ventilated and dry, avoid direct sunlight, and there should be no underground trenches or secret passages. Open fire is strictly forbidden and away from heat source.
Cylinder should be placed vertically, with the cap, properly fixed, prevent dumping.
When using, connect the exhaust nozzle of the cylinder valve with the production device. Gas leakage is strictly prohibited.
When used, the ambient temperature is between -20 degrees Celsius and 40 degrees Celsius
Avoid sun exposure and stay at least 10 meters away from an open flame.
The gas in the bottle shall not be used up, and the pressure shall be kept at not less than 0.5mpa.
For the intermittent system, the air of the high-purity nitrogen replacement system should be used first, and then the hydrogen chloride should be used to enter the system and discharge nitrogen, so that the system can carry out normal production. After production, hydrogen chloride in the high purity nitrogen replacement system is used to prevent system corrosion. After use, close the cylinder valve in time, remove the cylinder from the system, wipe each part of the cylinder valve, and tighten the bottle cap.
The use of self - contained cylinders, the valves must be changed by us. If the bottle valve is damaged, please ask our company to replace it.
Special cylinder for hydrogen chloride is strictly prohibited to refit other gases.
Cylinder body and valve are strictly prohibited oil pollution.
In the process of use, when the gas cylinder exhaust speed is relatively fast, the cylinder and pipeline crystallization is normal, and it is forbidden to be poured with hot water. In order to avoid frost in cylinder and pipeline, please use special gas supply device when the flow rate of gas consumption is greater than 2m3/h. We can provide special air supply equipment.
When the reliability of the cylinder cannot be determined, it should be tested immediately. The cylinder safety inspection period is two years, and the cylinder beyond the safety inspection period cannot be used.
The cylinder should be sent to us for maintenance after one year of use
The user unit shall organize workers and relevant management personnel to study the technical specification of hydrogen chloride safety, and be familiar with the accident hazards that may occur with hydrogen chloride gas and other relevant knowledge and information such as first aid and emergency measures.
Packing
Hydrogen chloride gas cylinder
Item | Volume (L) | Weight (Kg) | Weight of empty cylinder (Kg) |
1 ISO | 44 | 25 | 50 |
2 DOT | 47 | 27 | 52 |
The product can be put in the frame, transported by car or by sea.
20 feet container can hold 10 framework, about 160 cylinders; each frame with 16 cylinders or 20 cylinders.
Each frame with 16 cylinders or 20 cylinders.
Valve
Item | Pipe Orifice | Connector |
1 | PZ 22.8 | CGA330 |
2 | 3”/4-14 | CGA330 |
3 | 3”/4-14 | DISS634 |
4 | 3”/4-14 | DN-8 |
Packing in other sizes
250kg | Y cylinders |
550kg | T cylinders |
660kg | T cylinders |
500kg | New cylinders |
10T Truck
Parameter | ||
Truck body size (length * width * height):12390*2480*3000(mm) | ||
Size of steel tube (diameter * thickness * bottle length):599*16.8*10970(mm) | ||
The material:4130X | Medium:Hydrogen chloride | |
Nominal pressure:20MPa | The filling coefficient:0.57 | |
Nominal volume:18M3 | The valve interface:DIN-8 | |
The load:10Tons |