Rexroth A2FO Series Quantitative Piston Pumps High Pressure
Negotiable /Unit
Min.Order:1 Unit
Guangzhou Ouster Hydraulic Co., Ltd
series | A2FO Series Axial Piston Quantitative Pump |
Specifications | 10、12、16、23、28、32、45、56、63、80、90、107、125、160、180、200、250、355、500、710、1000. Series 6. |
Working pressure | Rated pressure 35 MPa, peak pressure 400 MPa. |
Characteristic | - The oblique axial quantitative pump is suitable for hydrostatic drive of open circuit.
|
Safety instructions:
A2FO pump is designed for use in open circuit.
- The project planning, installation and commissioning of the axial plunger unit must be carried out by qualified personnel.
Before using the axial plunger unit, please read the corresponding instruction manual. If necessary, you can get it from Bosch Rexroth.
During and shortly after operation, there is a risk of burning in the axial piston unit. Appropriate safety measures (such as wearing protective clothing) should be taken.
The characteristics of the axial plunger unit may vary with different working conditions (working pressure, oil temperature).
Work Pipeline Oil Port:
· Oil nozzles and fixed threads are designed according to the maximum prescribed pressure. Machine or system manufacturers must ensure that the safety factor of connecting components and pipes meets the specified working conditions (pressure, flow, hydraulic oil, temperature).
· Work pipeline nozzles and functional nozzles are only used in hydraulic pipelines.
- The data and instructions contained here must be followed.
The product cannot be approved as a component that follows the general mechanical safety concept of ISO 13849.
Overflow valves will be installed in the hydraulic system.
Use the following tightening torque:
· Connector:
Refer to manufacturer's instructions for tightening torque of the joints used.
· Install bolts:
For installation bolts with ISO metric threads in accordance with DIN 13 standard and with ASME B1.1 standard threads, we recommend that the tightening torque of each box be checked according to VDI 2230.
· Thread holes in the axial plunger unit:
The maximum allowable tightening torque MG Max is the maximum value for threaded holes and shall not exceed that value.
· Locking screw:
For the metal locking screw provided with the axial piston unit, the fastening torque MV required for the locking screw should be used.
Size | 10 | 12 | 16 | 23 | 28 | 32 | 45 | 56 | 63 | 80 | 90 | 107 | 125 | 160 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |||
Displacement | Vg | cm³ | 10.3 | 12 | 16 | 22.9 | 28.1 | 32 | 45.6 | 56.1 | 63 | 80.4 | 90 | 106.7 | 125 | 160.4 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |
geometric, per revolution | ||||||||||||||||||||||||
Nominal pressure | pnom | bar | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 350 | 350 | 350 | 350 | 350 | |
Maximum pressure | pmax | bar | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 450 | 400 | 400 | 400 | 400 | 400 | |
Maximum speed | nnom 1) | rpm | 3150 | 3150 | 3150 | 2500 | 2500 | 2500 | 2240 | 2000 | 2000 | 1800 | 1800 | 1600 | 1600 | 1450 | 1450 | 1550 | 1500 | 1320 | 1200 | 1200 | 950 | |
nmax 2) | rpm | 6000 | 6000 | 6000 | 4750 | 4750 | 4750 | 4250 | 3750 | 3750 | 3350 | 3350 | 3000 | 3000 | 2650 | 2650 | 2750 | 1800 | 1600 | 1500 | 1500 | 1200 | ||
Flow | at nnom | qV | l/min | 32 | 38 | 50 | 57 | 70 | 80 | 102 | 112 | 126 | 145 | 162 | 171 | 200 | 233 | 261 | 310 | 375 | 469 | 600 | 852 | 950 |
Power | at nnomand pnom | P | kW | 22 | 25 | 34 | 38 | 47 | 53 | 68 | 75 | 84 | 96 | 108 | 114 | 133 | 155 | 174 | 207 | 219 | 273 | 350 | 497 | 554 |
Torque 3) | at pnom | M | Nm | 66 | 76 | 102 | 146 | 179 | 204 | 290 | 357 | 401 | 512 | 573 | 679 | 796 | 1021 | 1146 | 1273 | 1393 | 1978 | 2785 | 3955 | 5570 |
Rotary stiffness | c | kNm/rad | 0.92 | 1.25 | 1.59 | 2.56 | 2.93 | 3.12 | 4.18 | 5.94 | 6.25 | 8.73 | 9.14 | 11.2 | 11.9 | 17.4 | 18.2 | 57.3 | 73.1 | 96.1 | 144 | 270 | 324 | |
Moment of inertia for rotary group | JTW | kg·m² | 0.0004 | 0.0004 | 0.0004 | 0.0012 | 0.0012 | 0.0012 | 0.0024 | 0.0042 | 0.0042 | 0.0072 | 0.0072 | 0.0116 | 0.0116 | 0.022 | 0.022 | 0.0353 | 0.061 | 0.102 | 0.178 | 0.55 | 0.55 | |
Maximum angular acceleration | ɑ | rad/s² | 5000 | 5000 | 5000 | 6500 | 6500 | 6500 | 14600 | 7500 | 7500 | 6000 | 6000 | 4500 | 4500 | 3500 | 3500 | 11000 | 10000 | 8300 | 5500 | 4300 | 4500 | |
Case volume | V | l | 0.17 | 0.17 | 0.17 | 0.2 | 0.2 | 0.2 | 0.33 | 0.45 | 0.45 | 0.55 | 0.55 | 0.8 | 0.8 | 1.1 | 1.1 | 2.7 | 2.5 | 3.5 | 4.2 | 8 | 8 | |
Weight (approx.) | m | kg | 6 | 6 | 6 | 9.5 | 9.5 | 9.5 | 13.5 | 18 | 18 | 23 | 23 | 32 | 32 | 45 | 45 | 66 | 73 | 110 | 155 | 325 | 336 |