Auto Standard Gurley Method Battery Separator Membrane Air Permeability Tester
Negotiable /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Ultra High Pressure Gas Transmittance Detector Gas Permeability Lab Tester
Free Shrink Film Testing Machine ASTM Cold/Heat Shrinkage Rate Lab Testing Apparatus
Flexible Packaging Leakage Testing Machine Bubble Method LEAK Lab Testing Equipment
Heat Gradient Testing Machine Five Point Thermal Sealing Equipment Flexible Packaging/ Plastic Film
High Precision Gurley Method Gas/Air Permeability Testing Machine
Auto Standard Gurley Method Battery Separator Membrane Air Permeability Tester
Product Detail
Application:
GTR-7001 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Auto Standard Gurley Method Battery Separator Membrane Air Permeability Tester
Features:
Ÿ Vacuum differential pressure method
Ÿ Patent technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Auto Standard Gurley Method Battery Separator Membrane Air Permeability Tester
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Dimension | 730mm * 510mm * 350mm |
Power supply | AC 220V 50Hz |
Net wt. | 63kg |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact