Rexroth A10VSO18 A10VSO28 A10VSO45 A10VSO71 A10VSO100 Hydraulic Piston Pump A10VSO Pumps
USD $1000 - $1100 /Piece
Min.Order:1 Piece
Jinan Yuanyi Hydraulic Equipments Co.,Ltd
Sauer 51D110 51D80 51D60 Hydraulic Motor 51D160 Piston Motor
Rexroth A4VSO125 A4VSO180 A4VSO90 Hydraulic Pump A4VSO Piston Pump
Concrete Mixer A2FM80 A2FM90 A2FM63 Hydraulic Motor A2FM125 Piston Motor
Sauer 90R180 90L180 90R130 90R250 Hydraulic Pumps 90R100 Piston Pumps
Sauer Danffoss 51D060 51D080 51D110 Hydraulic Piston Motor For Rigs
Rexroth A4VSO180 A4VSO250 A4VSO355 Hydraulic Pumps A4VSO Piston Pump
Rexroth A10VSO18 A10VSO28 A10VSO45 A10VSO71 A10VSO100 Hydraulic Piston Pump A10VSO Pumps
Series 31 model: A10VO18, A10VO28, A10VO45, A10VO71, A10VO100, A10VO140
Series 32 model: A10VO45, A10VO71, A10VO100, A10VO140, A10VO180
Series 52 & 53 model: A10VO10, A10VO18, A10VO28, A10VO45, A10VO63, A10VO85
Description
Open circuit
Control devices: DR, DRG, DFR, DFR1, DFLR, ED, FHD and EF.
Nominal pressure 280 bars. Peak pressure 350 bars.
- Hydraulic axial piston pump A10VO variable in swash plate design for hydrostatic transmissions in open loop circuit
- Flow is proportional to drive speed and displacement, by adjusting the swash plate angle it is possible to infinitely vary the flow
- Mounting flange acc. to SAE J744
- Flanged ports acc. to SAE J518
- 2 case drain ports
- Good suction characteristics
- Permissible working pressure 280 bar
- Low noise level
- Long service life
- Axial and radial loading of drive shaft possible
- High power to weight ratio
- Wide range of controls
-Short response times
Fluid
Prior to project design, please see our data sheets RE 90220 (mineral oil ) and RE 90221 (ecologically acceptable fluids) for detailed information on fluids and application conditions. When using ecologically acceptable fluids attention must be paid to possible limitations of the technical data.
Notes on the selection of hydraulic fluid
In order to select the correct fluid, it is necessary to know the operating temperature in the tank (open circuit) in relation to the ambient temperature. The hydraulic fluid should be selected so that within the operating temperature range, the viscosity lies within the optimum range (νopt.); see shaded section of the selection diagram. We recommend that the higher viscosity grade is selected in each case. Example: at an ambient temperature of X°C the operating temperature in the tank is 60 °C. In the optimum viscosity range νopt (shaded area), this corresponds to viscosity grades VG 46 or VG 68, VG 68 should be selected. Important: The leakage oil temperature is influenced by pressure and speed and is typically higher than the tank temperature. However max. temperature at any point in the system may not exceed 115 °C. At high temperatures please use FKM seals.
DG - two point, direct control
The pump can be set to a minimum swivel angle by connecting an external switching pressure to port X. This will supply the control piston directly with control oil; a minimum pressure of 50 bar is required.
DR - Pressure control
The pressure control serves to maintain a constant pressure in the hydraulic system, within the control range of the pump. The pump therefore supplies only the amount of hydraulic fluid required by the actuators. Pressure can be steplessly set at the pilot valve.
Technical Data Brueninghaus Hydromatik Rexroth A10VO
Table of values (theoretical values, without efficiency and tolerances; values rounded)