Biosafety cabinet manufacturers direct sales, professional exports to Australia, Spain and the United States
USD $2955 - $4733 /Case
Min.Order:1 Case
Box-type Muffle Furnace, focusing on the export of the United States, Canada and Spain
500 degrees high temperature electric blast drying oven high temperature resistance
High temperature electric blast dryer stainless steel inner, high quality export
High distribution version of vacuum drying ovenKZG, high quality export
A2 type biosafety cabinet is the safety equipment for research,teach and clinical examination in fields of microbiology,bio-medicine,genic recombination,animal experiments and biological.
It adopt special design and structure to offer safe protection to environment,operators and test items.
Parameter
A2-1000D | A2-1300D | A2-1000G | A2-1300G | ||
External (H*W*D) | 2060*1040*760
| 2060*1340*760
| 2060*1040*760
| 2060*1340*760
| |
Internal(H *W*D) | 660*960*535 | 660*1260*535 | 660*960*535 | 660*1260*535 | |
Average flow speed | In flow | 0.50m/s | |||
Down flow | 0.35m/s | ||||
Flow capacity | In flow | 270m3/h | 356m3/h | 270m3/h | 356m3/h |
Down flow, 70% | 563m3/h | 741m3/h | 563m3/h | 741m3/h | |
Exhaust, 30% | 270m3/h | 356m3/h | 270m3/h | 356m3/h | |
High efficiency filter | G style: ULPA filter, 99.999%; D style HEPA filter, 99.995%. | ||||
Noise | ≤65dB | ||||
Light | ≥650Lux | ||||
Cabinet | Outer:1.2mm cold steel,white epoxy resin paint, inner: 1.0mm304 S.S | ||||
Power supply voltage | 220-240VAC,50Hz,1Ph | ||||
power(W) | 300 | 350 | 300 | 350 | |
Weight(KG) | 175 | 210 | 175 | 210 |
Flow Mode
1. The ULPA filtered air.
2. Not filtered/might polluted air.
3. Incoming air
The fan suck the coming air from surrounds into grating in the front of working table to avoid to pollute table and samples, the incoming air won’t be mixed with cleaning air in the chamber. The coming air will go through the path and flow to the pressure chamber in the top.
30% air in the pressure chamber will be exhausted out through filter. The left 70% air will down to Filter then form cleaning air to flow to working area.
The stable and uniformity air flow will protect samples, to avoid cross infection in the chamber.
When the air approach to working table, the down flow will be parted two parts, one partial will Flow forwarding to grating, the other partial will flow backward.a little part of down flows after filtered will be sucked speedily to the holes of side area.
The inflow and down flow are mixed to form gas curtain to prevent the polluted gas to working area, and also avoid over-fall of chamber airs.
/biosafety-cabinet/20170531/17.html