Separation Performance Test of Mixed Gas in Separation Membrane Air Permeability Tester
USD $1 - $10000 /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Ultra High Pressure Gas Transmittance of Rubber Material Permeability Tester
Lithium Battery Separator Film Air Permeability Tester Standard Gurley Method Lab Test Machine
Battery Separation Charge And Discharge Performence Testing Equipment Air Permeability Tester
Gurley Method Sepatation Separator Membrane Air Permeability Tester
Separation Performance Test of Mixed Gas in Separation Membrane Air Permeability Tester
Product Detail
Application:
GTR-7001 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes.
Separation Performance Test of Mixed Gas in Separation Membrane Air Permeability Tester
Features:
Ÿ Vacuum differential pressure method
Ÿ Patent technology
Ÿ 3 specimens test simultaneously and independently
Ÿ Computer control
Ÿ One-button test, test automatically through whole process
Ÿ High accuracy vacuum sensors embedded in
Ÿ 3 Chambers with independent temperature sensor
Ÿ Test under various RH conditions with Humidity generator (optional)
Ÿ Environment temperature and humidity sensor inside
Ÿ Permeability coefficient ,solubility coefficient and diffusion coefficient test
Ÿ Chambers with water bath temperature control technology
Ÿ Unit based on embedded system,24bit Δ-Σ AD
Ÿ Multiple test modes optional
Ÿ Data curves display
Ÿ Traceable reference film calibration
Ÿ Supports DSM system (DSM, lab data management system)
Separation Performance Test of Mixed Gas in Separation Membrane Air Permeability Tester
Technical Indexes:
Test range | 0.01 - 190,000 cm3/m2·24h·0.1MPa (Standard) |
Resolution | 0.001cm3/m2·24h·0.1MPa |
Samples | 3, independent |
Vacuum accuracy | 0.1Pa |
Temperature range | 5C - 95C |
Temperature accuracy | ±0.1C |
Humidity range | 0%RH,35%RH-90%RH,100%RH (optional) |
Humidity accuracy | ±1%RH (optional) |
Sample thickness | less 5mm |
Sample size | >= 150mm * 94mm |
Test area | 48cm2 |
Test gas | O2, N2, CO2, He, etc |
Differential pressure | -0.1MPa - 0.1MPa |
Gas interface | Ф8mm |
Dimension | 730mm * 510mm * 350mm |
Power supply | AC 220V 50Hz |
Net wt. | 63kg |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact