Food Packaging Ethylene Oxide Printing Residue Tester Gas Chromatography Testing Machine
USD $1 - $10000 /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Gas Transmittance Testing Machine Heat Exchange Membrane Permeability Tester
Peeling Testing Machine Silicone Oil Paper Peeling Force Tester
Packaging Residue Total Migration Meter Flexible Packaging Migration Testing Machine
ASTM Automatic Water Vapor Permeability Testing Machine PET Films Humidity Transmittance Rate
Heat Gradient Testing Machine Five Point Thermal Sealing Instrument Thermal Sealing Strength Tester
Printing Residue Test Gas Chromatography Solvent Testing Machine Food Packaging
Product Detail
Application:
GC-7960 Ethylene Oxide Residue Tester applies to test of solvent residue on various printing films, laminated films, extrusion films, various drug-use films and sheets as well as various kinds of sterilization apparatus and instruments. It is one highly cost-effective tester and SYSTESTER launched GC-7960 specially for food & pharmaceutical industries, quality inspection departments as well as research and development institutions.
Printing Residue Test Gas Chromatography Solvent Testing Machine Food Packaging
Characteristics:
1. Professionally ethylene oxide residue test.
2. Microcomputer controls, LCD displays.
3. PVC keyboard, easy to operate.
4. Dual CPUs design, excellent electromagnetic interference protection.
5. Dual FID detectors, dual gas circuits system, self-diagnosis function.
6. Ignite automatically.
7. Constant and programming temperature control function.
8. Temperature control accuracy over 0.1°C.
9. 8 grades temperature programming function.(Personal customization available)
10. Temperature rising fast, highly efficient capillary column, zero-dead volume.
11. Bigger oven design.
12. Variable frequency cooling system, easy to do a nearest room temperature test.
13. Record parameters automatically even power’s down.
14. Over temperature protection function.
15. Carrier gas flow monitoring to protect TCD detector and oven column.
16. Self-diagnosis function, trouble is easy to resolve.
17. Powerful chromatographic work station.
Printing Residue Test Gas Chromatography Solvent Testing Machine Food Packaging
Indexes
1. Temperature Control:
Oven: room temperature +8~ 420°C, accuracy ±0.1°C (at 200°C)
Injector: room temperature +8~ 420°C, accuracy ±0.1°C (at 200°C)
Detector: room temperature +8~420°C, accuracy ±0.1°C (at 200°C)
2. Oven:
Temperature Control: room temperature +8~420°C, accuracy ±0.1°C (at 200°C)
Dimension: 280mm X 280mm X 250mm
Programmed Temperature: 8 grades. (Personal customization available)
Programmed Temperature rising rate: 1°C ~50°C
Dwell time at One Grade: 0~300min
3. FID Detector:
Detection Limit | ≤8×10-12 g/s (Hexadecane/Isooctane) |
Baseline Noise | ≤0.02 |
Baseline Drift | ≤0.15 |
Linearity | 106 |
Signal Stabilization Time | < 20min |
Ignition | Auto. |