Air Blowing Mini Optical Cable
Negotiable /Meter
Min.Order:10 Meters
FIBERLINK COMMUNICATION LIMITED
Fiberlink Mini Air Blown Micro Cables is the uni-tube design with small size, light weight, enhanced surface outer sheath fiber unit used for blowing into micro tube bundles by air flow. The outer thermoplastic layer provides a high level of protection and excellent installation properties. It is usually applied in FTTX.
Features
Special complex material loose tube, reduce the shrink of tube in cold temperature.
Accurate fibre length balance, stable mechanical and temperature performance.
Particular technique control, prevent sheath form crinkling during installation.
Structure Innovation in sheath, enhancing the blowing performance.
Applications
Suitable for ducts & aerial fiber optic cable
Local area network system
Long distance communication system
Specifications
Teeminal Index
Cable Type | FLK-MABC(MUT + Cable diameter) | |||
MUT2.0 | MUT2.3 | MUT2.5 | MUT2.8 | |
Fibre Count | 2~4 | 6~12 | 2~12 | 14~24 |
Thickness of HDPE sheath | Nominal value:0.20mm, Average value:0.15mm | |||
Fiber Type | G.G652D, G.657A1, G.657A2 & Multi mode fiber Optional | |||
Nominal Overall Diameter | 2.0±0.1mm | 2.3±0.1mm | 2.5±0.1mm | 2.8±0.1mm |
Weight | 4.0 kg/km | 5.0 kg/km | 6.0 kg/km | 7.0kg/km |
Cable Fibre Attenuation(single mode) | 0.35dB/km max @1310nm 0.22dB/km max @1550nm | |||
Max. Tensile Strength | 40N | 50N | 60N | 60N |
Max. Crushing force | 600N/100mm | |||
Min. Bending radius -Static / Dynamic | 10 / 20 outer Φ | |||
Temperature | Storage -30~+50℃;Installation-10~+40℃;Operation-20~+50℃ | |||
Cable service life (estimate value) | 25 years |
Blowing Performance
Blowing Tool | Typical blowing length | ||
PLUMETTAZ: PR-140,MiniJet-400 etc. Air pressure: 13 bar | Fiber Count | Duct type 3.5/5.0mm | Duct type 5.5/7.0mm |
2-12 fibers | ≥800m | ≥1500m | |
14-24 fibers | ≥500m | ≥1500m |
Mechanical Performance
Item | Testing Method | Testing Results | Specified Value | |
Tension Performance | IEC 60794-1-2-E1 | Optical fibre strain | Additional attenuation | Max. Tensile Strength = Short term Allowable tension≈2×(Long term AllowableTension) |
Short term:≤0.3% Long term:≤0.1% | Short term:Δa<0.10dB,Δa reversible;Long term: Δa ≤0.03dB | |||
Crush | IEC 60794-1-2-E3 | Short term:Δa<0.10dB,Δa reversible;Long term: Δa ≤0.03dBThe outer sheath has no visible crack. | Short termcrushing force=600NLong termcrushing force=300N | |
Repeated bending | IEC 60794-1-2-E6 | After test,Δa ≤0.03dB, The outer sheath has no visible crack | R=20outer Ф | |
Bending load=15N | ||||
Bending times=25 | ||||
Torsion | IEC 60794-1-2-E7 | After test,Δa ≤0.03dB, The outer sheath has no visible crack | Torsion angle = ±180℃ | |
Torsion load=15N | ||||
Torsion times=5 | ||||
Cable bend | IEC 60794-1-2-E11A | After test, The optical fiber can't be broken; the outer sheath has no visible crack | R=20 outer Ф10 TurnsCycles times=5 | |
All optical testing proceeded at 1550nm |