Package Printing Ethylene Oxide Residue Tester Gas Chromatography Detectors
USD $1 - $10000 /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Gas Transmittance Rate Flexible Package LLDEP Film Lab Tester Oxygen Permeability Testing Machine
Free Falling Dart Impact Testing Machine Method A Method B ASTM Plastic Film Impact Test
Atmosphere Preservation Packaging Migration Testing Apparatus Total Migration Of Modified
Artificial Intelligence Model Gas Permeability Tester Mixed Gas ASTM F1249 Transmittance Tester
Sealing Strength Testing Instrument Of Jelly Cup Cover Film Plastic Thermal Strength Testing Machine
Printing Residue Test Gas Chromatography Solvent Testing Machine Food Packaging
Product Detail
Application:
GC-7960 Ethylene Oxide Residue Tester applies to test of solvent residue on various printing films, laminated films, extrusion films, various drug-use films and sheets as well as various kinds of sterilization apparatus and instruments. It is one highly cost-effective tester and SYSTESTER launched GC-7960 specially for food & pharmaceutical industries, quality inspection departments as well as research and development institutions.
Printing Residue Test Gas Chromatography Solvent Testing Machine Food Packaging
Characteristics:
1. Professionally ethylene oxide residue test.
2. Microcomputer controls, LCD displays.
3. PVC keyboard, easy to operate.
4. Dual CPUs design, excellent electromagnetic interference protection.
5. Dual FID detectors, dual gas circuits system, self-diagnosis function.
6. Ignite automatically.
7. Constant and programming temperature control function.
8. Temperature control accuracy over 0.1°C.
9. 8 grades temperature programming function.(Personal customization available)
10. Temperature rising fast, highly efficient capillary column, zero-dead volume.
11. Bigger oven design.
12. Variable frequency cooling system, easy to do a nearest room temperature test.
13. Record parameters automatically even power’s down.
14. Over temperature protection function.
15. Carrier gas flow monitoring to protect TCD detector and oven column.
16. Self-diagnosis function, trouble is easy to resolve.
17. Powerful chromatographic work station.
Printing Residue Test Gas Chromatography Solvent Testing Machine Food Packaging
Indexes
1. Temperature Control:
Oven: room temperature +8~ 420°C, accuracy ±0.1°C (at 200°C)
Injector: room temperature +8~ 420°C, accuracy ±0.1°C (at 200°C)
Detector: room temperature +8~420°C, accuracy ±0.1°C (at 200°C)
2. Oven:
Temperature Control: room temperature +8~420°C, accuracy ±0.1°C (at 200°C)
Dimension: 280mm X 280mm X 250mm
Programmed Temperature: 8 grades. (Personal customization available)
Programmed Temperature rising rate: 1°C ~50°C
Dwell time at One Grade: 0~300min
3. FID Detector:
Detection Limit | ≤8×10-12 g/s (Hexadecane/Isooctane) |
Baseline Noise | ≤0.02 |
Baseline Drift | ≤0.15 |
Linearity | 106 |
Signal Stabilization Time | < 20min |
Ignition | Auto. |
Certificates
Products Catalog
What we cab provide
Packages & Logistics
Export Areas
Contact