Eurovent A++ 24000btu split air conditioner, duct air conditioner, inverter air conditioner
USD $465 - $465 /Unit
Min.Order:200 Units
2015 euro union market ERP4.0 A++ lastest model split air conditioner
split Air Conditioner Specification Sheet
Declared cooling capacity | W | 6400(1500~7500) | |
Declared heating capacity | W | 6600(1500~8000) | |
SEER measured | W/W | 6.100 | |
Energy Class | W/W | A++ | |
SCOP Average measured | W/W | 3.900 | |
Energy Class | W/W | A+ | |
SCOP Average declared | W/W | 4.000 | |
Energy Class | W/W | A+ | |
Moisture removal | Liters/h | 1.6 | |
Indoor sound power | High | dB(A) | 60 |
Med. | dB(A) | 56 | |
Low | dB(A) | 52 | |
Outdoor sound power | High | dB(A) | 68 |
Med. | dB(A) | 66 | |
Low | dB(A) | 62 | |
Electrical Data | |||
Power supply | |||
Voltage Range | V | 165~265 | |
Operating current | Cooling | A | 9.8(1.7~13.5) |
Heating | A | 8.5(1.5~15.5) | |
Power consumption | Cooling | W | 2150(350~2800) |
Heating | W | 1850(300~3200) | |
Refrigerating System | |||
Refrigerant | Gram | R410A/2.05kg | |
Compressor | Type | Rotary | |
Model | ATL165UDPC9AU | ||
Frequency range | 10~120 | ||
MFG | HIGHLY | ||
Fan System | |||
Indoor air circulation Cooling/heating | m3/h | 1100/1200 | |
Indoor fan type | Cross Flow | ||
Indoor fan speed H/M/L | Cooling | rpm | 1300/1150/950 |
Heating | rpm | 1300/1150/950 | |
Dry | rpm | 950 | |
Sleep | rpm | 950 | |
Indoor fan motor output | W | 50 | |
Outdoor air circulation Cooling/heating | m3/h | 3200/3200 | |
Outdoor fan type | Propeller fan | ||
Outdoor fan speed | rpm | 1000/860/700 | |
Outdoor fan motor output | W | 115 | |
Connections | |||
Connecting Wiring | Size x Core number | 4*1.5mm2 | |
Expension device | Capillary | ||
Connecting Pipe | Gas | Inches | 5/8” |
Liquid | Inches | 1/4“ | |
Others | |||
Net dimensions | Indoor | mm | 1033×313×202 |
(W x H x D) | Outdoor | mm | 900×315×650 |
Net weight | Indoor | kg | 14 |
Outdoor | kg | 50 | |
Packing dimensions | Indoor | mm | 1958×602×475 |
(W x H x D) | Outdoor | mm | 1103*400*300 |
Gross weight | Indoor | kg | 17 |
Outdoor | kg | 59 | |
Loading Capacity | 40'HQ | 145 |
Split air conditioner Optional functions:
(If you need below add functions, please let me know)
1.Titangold heat exchanger
2. Active carbon Filter
3. Photocatalyst Filter
4. Catechin Filter
5. Vitamin-enriching Filter
6. Nano Silver Filter
7. Air Ionizer
Samples is accept less than five units each model .
Delivery time two weeks.
Three years warranty for whole unit and five years warranty for compressor.
Wall Split air conditioner Packing Show
Window air conditioner Packing Carton:
Floor Standing air conditioner Packing:
Air conditioner knowledge you should learn:
1. Why the heating of the air conditioner does not function?
Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual.
2. Why the air conditioner does not blow out hot air until several minutes after it is activated?
Answer: This is because when the heating mold just started, the temperature of evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reach the set temperature. Thus, there will not be any wind blow out at the beginning.
3. Why the air conditioner does not work for the first 3 minutes, after it is restarted after a sudden power lost?
Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes.
4. Why the capacity of new air condition seemed not strong enough to cool down the room temperature?
Answer: There could be various reasons:
1) The capacity is insufficient, professional will be necessary for checking.
2) Wrong mode of air conditioner is brought, as the choice of models has a direct relationship with the following conditions:
A. The area of the room.
B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of room wall, large glass window and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as dining room and living room.
To our experience, capacity of air conditioner = room area X cooling load, cooling load can be between 160 to 220, depend on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room and 220 for a dining room. Commercial areas should be estimated according to real situations.