DC inverter high efficiency wall split air conditioner
USD $480 - $480 /Unit
Min.Order:100 Units
Eurovent Supreme Energy Efficiency A++ SCOP4.0 lower noise 24000btu wall split air conditioner
Wall Split Air Conditioner Specification Sheet
Model | OS-24HRFN1 | ||
Power supply | Ph-V-Hz | 220-240V~ 50Hz, 1Ph | |
Rated Cooling | Capacity | Btu/h | 22000(7240~24640) |
Cooling Power input | W | 171~2780 | |
Cooling Current | A | 0.74~12.09 | |
Rated Heating | Capacity | Btu/h | 25000(4600~30000) |
Heating Power input | W | 235~3140 | |
Heating Current | A | 1.02~13.65 | |
Seasonal Cooling | Pdesignc | kW | 6.4 |
SEER | W/W | 6.1 | |
Energy Efficiency Class | A++ | ||
Heating(Average ) | Pdesignh | kW | 5.2 |
SCOP | W/W | 4.0 | |
Energy Efficiency Class | A+ | ||
Tbiv | ℃ | -7 | |
Heating(Warmer ) | Pdesignh | kW | 7.1 |
SCOP | W/W | 4.8 | |
Energy Efficiency Class | A++ | ||
Tbiv | ℃ | 5 | |
Tol | ℃ | -15 | |
Moisture Removal | L/h | 2.3 | |
Max. input consumption | W | 3100 | |
Max. current | A | 14.5 | |
Starting current | A | ---- | |
Compressor | Model | DA150S1C-20FZ | |
Type | Twin-rotary | ||
Brand | TOSHIBA | ||
Capacity | Btu/h | 15286 | |
Input | W | 1150 | |
Rated current(RLA) | A | 9.7 | |
Locked rotor Amp(LRA) | A | ---- | |
Thermal protector | KSD301 | ||
Thermal protector position | EXTERNAL | ||
Capacitor | uF | --- | |
Refrigerant oil/oil charge | ml | ESTER OIL VG74/500 | |
Indoor fan motor | Model | WZDK58-38G | |
Brand | Shibaura | ||
Output | W | 58 | |
Capacitor | uF | - - | |
Speed(Hi/Mi/Lo) | r/min | 1180 / 1100 / 900 | |
Indoor coil | a.Number of rows | 2 | |
b.Tube pitch(a)x row pitch(b) | mm | 21x13.37 | |
c.Fin spacing | mm | 1.3 | |
d.Fin type (code) | Hydrophilic aluminium | ||
e.Tube outside dia.and type | mm | Φ7, innergroove tube | |
f.Coil length x height x width | mm | 780x336x26.74 | |
g.Number of circuits | 4 | ||
Indoor air flow (Hi/Mi/Lo) | m3/h | 1150/1070/880 | |
Indoor sound pressure level (Hi/Mi/Lo) | dB(A) | 49/43/36 | |
Indoor sound power level (Hi) | dB(A) | 62 | |
Indoor unit | Dimension(W*D*H) | mm | 1045x235x315 |
Packing (W*D*H) | mm | 1135x395x315 | |
Net/Gross weight | Kg | 12/15.2 | |
Outdoor fan motor | Model | WZDK50-38G | |
Brand | Shibaura | ||
Output | W | 50 | |
Capacitor | uF | - - | |
Speed | r/min | 800 | |
Outdoor coil | a.Number of rows | 2 | |
b.Tube pitch(a)x row pitch(b) | mm | 25.4x22 | |
c.Fin spacing | mm | 1.4 | |
d.Fin type (code) | Hydrophilic aluminium | ||
e.Tube outside dia.and type | mm | Φ9.52,innergroove tube | |
f.Coil length x height x width | mm | 766x660x44 | |
g.Number of circuits | 4 | ||
Outdoor air flow | m3/h | 2700 | |
Outdoor sound pressure level | dB(A) | 60 | |
Outdoor sound power level | dB(A) | 67 | |
Outdoor unit | Dimension(W*D*H) | mm | 845x320x700 |
Packing (W*D*H) | mm | 965x395x755 | |
Net/Gross weight | Kg | 47 / 50 | |
Refrigerant | Type | R410A | |
GWP | 1975 | ||
Charged quantity | Kg | 1.95 | |
Design pressure | MPa | 4.2/1.5 | |
Refrigerant piping | Liquid side/ Gas side | mm(inch) | Φ9.52/Φ15.9(3/8"/5/8") |
Max. refrigerant pipe length | m | 30 | |
Max. difference in level | m | 20 | |
Connection wiring | 2.5(Optional) | ||
Plug type | -- | ||
Thermostat type | Remote Control | ||
Operation temperature | Indoor(cooling/ heating) | ℃ | 17~32/0~30 |
Outdoor(cooling/heating) | ℃ | -15~50/-15~30 | |
Application area | m2 | 32-53 | |
Qty’per 20’ /40’ /40'HQ | 69/140/160 |
Features:
On the basis of low noise air duct system and quiet design, you can shut off the AC beep and display by pressing mute operation to create a super quiet environment.
Apart from conventional remote control, Aurora split provide a variety of optional, including wired control, front desk control and central control.
Optional functions: (If you need below add functions, please let me know)
1. Active carbon Filter
2. Photocatalyst Filter
3. Catechin Filter
4. Vitamin-enriching Filter
5. Nano Silver Filter
6. Air Ionizer
1. Olyair Appliances insist high quality products reach every clients are safe without worry, so we will fully test each pc of product before leave factory.
2. As HVAC products we provide three year warranty for whole unit and compressor all use famous brand like toshiba, rechi etc.
and it lasts five years warranty also.
3. Each full container we will free to combine with 0.5%-1% spare parts based on each products request.
4. Olyair Provide OEM service which will in responsible for design the indoor and outdoor carton box. If you need have own panel design reqiuest just contact us we will ask engineer to give a strong idea for your long term development.
5. In general, when we receive your inquiry message, our information dept will send related colleage in the first time. So you will receive a reply within one hour. And if no any response, please contact our service team or visit our web to get some contact information.
6. We thank you for each client to read our any products in the web, so please let both of us value time, before send inquiry. please consider the products and it's specification you really need. Sometimes, some inquiry no any subject and don't confirm what they want, but just request to inform the payment terms and MOQ which made us difficult in reply an inquiry.
Wall Split Packing
Window Packing Carton:
Floor Standing Packing:
1. Why the heating of the air conditioner does not function?
Answer: Our remote control is designed to have both ‘cooling only’ mold and ‘cooling & heating’ mold. Users need to activate either the ‘cooling only’ mold or the ‘cooling & heating’ mold. If ‘cooling only’ mode is activated, the heating function of the air conditioner will not work, it will starting heating up the room temperature only when you turn it into ‘cooling & heating’ mold. The way of setting is demonstrated in detail in the user’s manual.
2. Why the air conditioner does not blow out hot air until several minutes after it is activated?
Answer: This is because when the heating mold just started, the temperature of evaporator is relatively low and the wind blow out would be cool. Therefore, there has designed a function of cool air protection, which will stop the indoor fan from working until the evaporator reach the set temperature. Thus, there will not be any wind blow out at the beginning.
3. Why the air conditioner does not work for the first 3 minutes, after it is restarted after a sudden power lost?
Answer: This is because our air conditioning has been set up with the power lost memory function (AUTO - RESTART), when suddenly power off and then immediately power on, the air conditioner will operate according to the same setting before the power off. Therefore, in order to prevent the impact of imbalance system to the compressor on its startup, the compressor will re-start operating 3 minutes delay. Thus, the condition will not either heat up or cool down the room temperature in these 3 minutes.
4. Why the capacity of new air condition seemed not strong enough to cool down the room temperature?
Answer: There could be various reasons:
1) The capacity is insufficient, professional will be necessary for checking.
2) Wrong mode of air conditioner is brought, as the choice of models has a direct relationship with the following conditions:
A. The area of the room.
B. The cooling load of the room. It is related to the heat leakage, which is affected by the thermal insulation of room wall, large glass window and no. of heating source such as high voltage home appliances. The heat leakage will also be affected in places such as dining room and living room.
To our experience, capacity of air conditioner = room area X cooling load, cooling load can be between 160 to 220, depend on the heat leakage. For example, if there are not any large voltage home appliances and the thermal insulation is ok, the cooling load of a single room can be estimated as 160, and 170 for a double room, 200 for a living room and 220 for a dining room. Commercial areas should be estimated according to real situations.
Our client from Euro union Countries should know below request before order air conditioner into your country.
In the lastest 2013, July, Euro union countries has below:
1.Austria
2.Belgium
3.Bulgaria
4.Cyprus
5.Croatia
6.CzechRepublic
7.Denmark
8.Estonia
9.Finland
10.France
11.Germany
12.Greece
13.Hungary
14.Ireland
15.Italy
16.Latvia
17.Lithuania
18.Luxembourg
19.Malta
20.Netherlands
21.Poland
22.Portugal
23.Romania
24.Slovakia
25.Slovenia
26.Spain
27.Sweden
28.United Kingdom
1. As EU requirement on air conditioner and single duct and double duct portable air conditioner is ERP standard.
And the energy efficiency will higher and higher which move step by step. Some client if not in HVAC region may not be very clear the policy. Below chart in each degree to show you how different on the new ERP stanard compare old EER rating.
Energy label Difference:
Olyair models from residential to commercial are reaching New class A ranking, the highest level that is now shown on energy label in Europe union.
New Energy Labelling Requirement (EU) 626/2011
• Three climate zones for heating
(Average zone is mandatory, warmer and
colder zone are voluntary)
• Seasonal efficiency
(performance based on multiple part loads
calculation)
Sound power level
• Rated efficiency indicates performance only at a rated condition.
Seasonal efficiency indicates performance at an entire cooling and heating season, which better matches the actual operation.
High Efficiency