HY-DPM11 stack dust concentration opacity analyzer exinction index monitor
USD $5,500 - $5,800 /Set
Min.Order:1 Set
Lixian Instrument Scientific Co., Ltd.
Brief introduction
HY-DPM11 is using optical transmission principle to measure the dust concentration in flue gas.
Detection of light path across the flue, double light path measurement system has a high brightness LDE light source is installed in the transmitting / receiving end beam, which emit light through the optical splitter road a two part: through the transmission optical lens to the reflective end, as part of the reference signal into another reference detector; a part of the detection light through the flue dust into the reflection unit, is reflected back to the transmitter / receiver optical focusing lens in the end after entering into the detector detection, signal detection. By calculating the ratio of the signal intensity on the two detectors, we can get the light transmittance / resistance / dust concentration value.
Features
Ensure emission of dust under control limitation
Monitoring working status of dust remover in factory.
Monitoring dust concentration in production
Industrial combustion efficiency monitoring
Assessment of process control
Technical parameter
measurement system | ||
Working principle: | Optical transmission method; | |
Light source: | Modulation of high intensity LED, its wavelength 637nm; | |
Measure range: | opacity: | 0-20% or 0-100% |
transmission: | 0-100% | |
dust concentration: | (0-999)mg/M3 | |
Accuracy: | ± 0.4% of reading | |
Drift: | < 1% /month | |
Resolution: | 0.1%; | |
Response time: | 5 sec to reach max value | |
Temp of flue gas: | 65 - 650℃ | |
Optical path length: | 0.5 - 10 meter standard type (other length can be customized) | |
Calibration: | Manual zero and range check, conform to USA EPA regulations; | |
linearity: | Equipped with three sets standard calibration lens | |
I/O | ||
Analog output: | 2 ways of 4-20mA output(Max.500Ω); | |
Digital output: | 1 way RS485 | |
Relay output: | Two way alarm relay(Alarm value can be set via operation panel) | |
Display: | 32 bits LCD | |
Key board input: | 6 pcs micro touch button input | |
Basic parameter | ||
Material of body: | Aluminum material coated,conform to IP65; | |
Environmental temperature: | -30 ~ +70℃; | |
Power supply: | 220V DC,10VA; | |
Blowback gas requirement: | Compressed air 80 L/h @ 1bar; |
Dear customer:
You see on our website products quotation, just a market reference price. We can according to customer specific requirements to give the actual price.
Dear customer, We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history . Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science. Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system. If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba We firmly believe that science and technology is no boundaries Our mission is to make every effort to contribute to all humanity. |