HAD - V1.2 Filter integrity tester
USD $6,200 - $8,500 /Set
Min.Order:1 Set
Lixian Instrument Scientific Co., Ltd.
HAD - V1.2 Filter integrity tester, filter integrity testermodels
The characteristics of the instrument and advantages:
1 standardized automatic filter material infiltrates program: automatic filter material infiltrates through a standardized procedure, ensure the filter material is completely liquid infiltration, with the subsequent test work, will not affect the downstream of the aseptic condition, meet the requirements of the on-line testing.
2 advanced data processing technology, adopting the advanced artificial intelligence technology, real time changing apparent diffusion flow and data flow is applied to the analysis of knowledge
Don't spread flow, viscous flow pattern, can accurately identify filter bubble point values, the test results of membrane filter/filter bubble point and real bacteria to closure
Performance relationship is better.
3 large capacity data storage function, can save 500 groups of test results and the test curve.Can be connected with PC to realize unlimited storage
4 HAD - V4.0 full-automatic filter integrity detector is the first present domestic filiter by the measured volume upstream of international diffusion flow testing instrument. And can be online with water immersion method "test" hydrophobic filter, solved the residue with organic solution infiltrationthe problem.
5 the adoption of advanced algorithms and filtering method, the instrument has the stability and reliability can be comparable to those of foreign detector, solves the countriesIn the common fault of the instrument is not stable, precision reaches one percent.
6 intake unit of instrument adopt fully automatic digital control, greatly increase the stability of the testing process, completely devoid of detector needs to be at home
Manufacturer of professional use adjustable inlet knob control inlet velocity of the original method.
7 can realize the integrity of the large capacity filter test. Our detector in view of the large capacity filter done a special design, the integrity of the insurance
Card when measuring multi-fiber filters, measuring accuracy will not diminish, measurement speed will not change.
8 instrument of core parts are imported, and used in the design process for the safety of the detailed analysis, in ensuring the basic electricalUnder the premise of full and mechanical safety, to each link of the process of operation safety.
9 have English and digital input function, convenient and direct customer input different batch number and serial number, conform to the new version of GMP implementation guidelines.
10 domestic first launched ultrafiltration membrane integrity testing functions, meet different customers' requirements.
Scope of application:
Wafer membrane filter (Disc be) : 25 mm to 300 mm Φ Φ various membrane filter
Standard folding filter (SHAD – andard carHAD - ridge) : 2.5 to 40 "and" core core 1 to 15
Capsule type filter (Capsule),
Small filter (Mini carHAD - ridge)
Air filter to 40 test 2.5 ""
Ultrafiltration membrane
HAD - V1.2 Filter integrity tester, filter integrity tester models
Online testing, do not interfere with the downstream aseptic condition;
Have system self-check function, the system tightness, wrong operation, with an error function;
Microcomputer control automatic detection with bubble point scanning, fast bubble point tests and pressure maintaining method and so on the many kinds of test functions;
Real-time print test results;
Filter can be used to test the single core and multicore filter;
Can enter the upstream diffusion flow volume.
The performance parameters:
Power requirements/power 170-240 v AC, 50/60 hz.85 w.
The maximum operating pressure 7999 mbar
The minimum inlet pressure 3000 mbar
Installation dimensions 240 (width) x 380 (deep) x 280 (1) x 220 (2)
Maximum test pressure test range: 500-6900 mbar
Testing precision sensitivity: + / - 1.0 mbar; Bubble point: + 75 mbar;
Operating conditions of ambient temperature: + 5 ℃ ~ + 35 ℃;
Relative humidity: 10-80%
Take quick bubble point testing: 8 min plus or minus 2 min; The bubble point scanning: 20 min plus or minus 2 min;Diffusion flow: 10 min plus or minus 2 min
Print function Chinese print output test parameters and test results
History function store 20 groups of test results
Screen size: 73 * 39 mm;monochromatic
Chinese language options
Dear customer,
We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .
Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.
Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.
If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba
We firmly believe that science and technology is no boundaries Our mission is to make every effort to contribute to all humanity. |