SM-500S Portable Patient Monitor
Introduction
Medical electrical equipment GB 9706.1-2007, Part I: General requirements for safety
GB 9706.25-2005 Medical electrical equipment Part 2
27: ECG monitoring equipment safety requirements .12 inch widescreen TFT, Resolution ratio: 800×600, up to12 waveforms ;Display ECG, SpO2, pulse rate, NIBP, respiration, temperature Plumbic acid battery.
Features
12 inch color TFT display, up to 12 waveforms
One level menu, easy to use
Parameters including ECG/RESP, SpO2 , NIBP, TEMP, Pulse Rate and IBP(optional)
Maximum 720 hour graphic and tabular trends of all parameters
Built-in recorder and battery
Suitable for adult, pediatric and neonatal patient
Arrhythmia analysis, ST calculation, Pace analysis
Anti-ESU, anti- defibrillator
Standard network interface, can connect to Central monitor system
Techinical Parameter
SFDA classificationClass II
Anti-electroshock degreeClass I equipment with internal power supply
Anti-electroshock degree TEMP/SpO2/NIBP:ECG/RESP
Explosion proof level Ordinary equipment,without explosion proof
Harmful liquid proof degreeOrdinary equipment,without liquid proof
Working systemContinuous running equipment
size 300 ×275 ×150 mm
Weight 4 kg
Power Supply 100~240 VAC, 50/60 Hz, Pmax=90VA Fuse T1.5A 5 Battery 2.6 Ah 12V rechargeable battery
Operating time after full charge is more than 1 hours
Operating time after the first alarm of low battery will be about 5 minutes
Maximum charging time is less than 6 hours.
6 Signal Interface
Network interface standard RJ45 Socket
7 Storage
Trend 720 hours
NIBP review 1000 NIBP events
Wave review 2 hours
Alarm review 200 alarm events
All storage data are non volatile.
8 Environment
8.1 Temperature
Working 0 ~ 40 °C
Storage -20 ~ 50°C
8.2 Humidity
Working 15% - 90 % (no coagulation)
Storage 15% - 90 % (no coagulation)
8.3 Atmospheric pressure
Working 86.0 kPa ~ 106.0kPa;
Storage 86.0 kPa ~ 106.0kPa
9 ECG Specification
9.1 Heart rate calculation method
Since the first occurrence of heart rate to heart rate occurred in the second interval T1; second heart rate, heart rate occurred to a third place time interval T2; continuous record 10 times, and then calculated the average interval of 10, must the heart rate per minute. 3s ~ 10s refresh every heart.
9.2 Heart rate meter accuracy and arrhythmia response
Monitor the 20s stable time after figure ECG heart rate a wave group): heart rate display 40bpm ± 5bpm; b): heart rate display 30bpm ±5bpm; c): heart rate display 120bpm±5bpm; d): heart rate display 45bpm±5bpm
A) Couple rhythm — two waves of duration is 1500ms; if the calculation all the QRS complex, heart rate to 80bpm, if only large R wave or S-wave, the heart rate to 40bpm.
B) Slow change couple rhythm — if the calculation all the QRS complex, heart rate to calculate 60bpm, if only large waves, heart rate to 30bpm.
C) Fast couple rhythm — if the calculation all the QRS complex, heart rate as 120bpm.
D) bi-directional contraction —
if you calculate the QRS complex, heart rate to calculate 90bpm, if only large waves, heart rate to 45bpm.
Dear Customers, We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history . Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science. Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system. If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba We firmly believe that science and technology is no boundaries Our mission is to make every effort to contribute to all humanity. |