DNM-9606 Elisa reader

Brand Name PULANG
Place of Origin Shaanxi, China
Model Number DNM-9606-XIN
Type Biochemical Analysis System

Product Features

 Introduction

The instrument and through the State Drug Administration registered supporting the use of ELISA reagents can be used for hospitals and departments ELISA detection ELISA plate, plates and other test work and chemistry, biochemistry and other aspects of trace analysis appropriate testing.

Feature

1 Instrument has the power on self test, auto-select filter, the vibration plate and communication

2  Instrument can store 200 test procedures, keep the 200 groups of parameters and their calibration curve, the entire board storage of 105 test data set, which DNM-9606F enzyme analyzer can store 126 test procedures, 126 parameters and calibration curves of group

3 Instrument with a single, dual-wavelength detection for users to choose two functions;

4 Instrument has absorbance, qualitative and quantitative analysis;

5 Instrument can output 10 kinds of data, namely, absorbance, the critical value, yin and yang of the results, semi-quantitative value, concentration, normal reference values to determine the results, quality control data, quality control chart, calibration curve;

6 To any storage, query and print all 6 items of data on quality control and all month quality control curve, which DNM-9606F enzyme analyzer can store, query and print all 5 items of data on all month quality control and all month quality control curve

7 Through the touch screen to enter uppercase and lowercase letters and Chinese characters are three input methods to choose from, including DNM-9606F enzyme analyzer input through the panel, both uppercase and lowercase letters input method for users to choose;

8 You can print a comprehensive report of 1000 patients, of which DNM-9606F enzyme analyzer does not have this feature.

Technical Parameter

1  Instrument configuration the center wavelength of interference filters accuracy: ± 3.0, half-width ≤ 12

2  Operating wavelength range of the instrument :400nm-800nm, equipment standard: 405nm, 450nm, 492nm, 630nm

3  Absorbance measurement accuracy and linearity error should be consistent with provisions of the table

Absorbance range 

Accuracy requirements

Linearity Error%

0-1.5

±1.0% or   ±0.01

±1.0

1.5-3.0

±3.0% or    ±0.05

±3.0

3.0-4.0

±8.0% or   ±0.15

±5.0

4  Measurement repeatability should not exceed 0.5%

5  Stability:

1) The instrument in 10min absorbance variation caused by internal drift should be less than ± 0.005A

2) The instrument absorbance change when the supply voltage is 220V ± 10%, causing the change should not ± 0.005A.

 

DNM-9606 Elisa reader 
 

Dear customer:

We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .

Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.

Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.

If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba.

We firmly believe that science and technology is no boundaries.

Our mission is to make every effort to contribute to all humanity.

You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now