SV-5QC(B) exhaust gas non-dispersive infrared analyzer with imported Capelec sensor
USD $1,416 - $1,770 /Unit
Min.Order:1 Unit
Lixian Instrument Scientific Co., Ltd.
Brief introduction
SV-5QC type of vehicle exhaust gas analyzer in the French Capelec imported movement by non dispersive infrared absorption method, the microcomputer analysis, can be directly measured in motor vehicle exhaust emissions of HC, CO and CO2 concentration; using electrochemical principle to measure emissions of no and O2 concentration, and excess air coefficient is calculated according to the measured Co, CO2, HC and O2 concentration
Features
Meet the national GB/T18285-2005 standards.
Using the French Capelec original import movement, using the principle of non - absorption infrared absorption method, the HC, CO, CO2, and O2 were measured by micro computer analysis, the concentration of and NO were measured by electrochemical principle.
With idle speed, double idle test function, you can choose oil temperature measurement function.
Configuration 7 inch high brightness LCD display, support multi language operation menu.
Auto calculation shows that the excess air coefficient is a value.
Equipped with RS-232C digital serial communication interface, convenient networking.
Have more than 500 sets of data storage, check function.
Equipped with built-in printer
The exhaust gas detection can be carried out for the fuel of three kinds of natural gas, liquefied gas and gasoline.
The automobile power supply inverter can be configured to facilitate the test of tail gas.
Technical parameters
Using environmental conditions:
Temperature: 0 ~ 40
Humidity: no more than 95%
Atmospheric pressure: 70 ~ 106kPa
Power supply: AC220V + 10%; 50Hz + 1Hz
Measurement range:
HC: 0 ~ 20000 (PPM) Vol
CO: 0 ~ 15 (%) Vol
CO2: 0 ~ 20 (%) Vol
O2:0 ~ 25 (%) Vol
NO: 0 ~ 5000 (PPM) Vol
A: 0-9.9999
Engine speed (RPM): 300 ~ 9999rpm (optional)
Temperature: 0 ~ 120 degrees (optional)
Measurement accuracy:
1ppm HC:
CO: 0.001%
CO2: 0.01%
O2: 0.1%
NO: 1ppm
Item | Measure range | Absolute error | Relative error |
HC | (0-20000)ppm | ±5% | 10ppm |
CO | (0-15)% | ±5% | 0.03% |
CO2 | (0-20)% | ±5% | 0.40% |
O2 | (0-25)% | ±3% | 0.10% |
NO | (0-5000)ppm | 8% | 25ppm |
The response time is less than 10s, O2; NO is not greater than 15s
The preheating time: 10 minutes (for 3 minutes warm-up emergency detection)
Dear customer,
We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .
Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.
Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.
If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba
We firmly believe that science and technology is no boundaries
Our mission is to make every effort to contribute to all humanity.
Your earlier friendly enquire from us would be highly appreciated. Thanks in advance!